Schneider Electric BJA360306 Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, CBA
Schneider Electric
$2,892.00
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 30A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with a CBA phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Height:
- 137 mm
- Control Type:
- toggle
- Length:
- 20 mm
- Pollution Degree:
- 3 IEC 60947-1
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz UL 489
- Mounting Mode:
- I-Line
- Range:
- PowerPact
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Quality Labels:
- CE
- Device Short Name:
- BJ 030
- Ambient Air Temperature For Storage:
- -50-85°C
- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
- Halogen Content Performance:
- Halogen free product
- Circuit Breaker Application:
- HACR rated
- Eu Rohs Directive:
- Compliant
- Suitability For Isolation:
- yes IEC 60947-2
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Poles Description:
- 3P
- Ik Degree Of Protection:
- IK07 conforming to IEC 62262
- Standards:
- NEMA AB1 || GB 14048.2 || UL 489 || CSA C22.2 No 5 || EN/IEC 60947-2 || NMX J-266 || EN/IEC 60947-5-1
- Breaking Capacity Code:
- J
- Color:
- Gray RAL 7016)
- Product Or Component Type:
- circuit breaker
- Rohs Exemption Information:
- Yes
- Net Weight:
- 1.315 kg
- Wire Stripping Length:
- 20 mm
- Pvc Free:
- Yes
- Weight:
- 1.315 kg
- Environmental Disclosure:
- ENVPEP1610005EN
- Breaking Capacity:
- 100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
- Phase Connection:
- CBA
- Mercury Free:
- Yes
- Connection Pitch:
- 27 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Network Frequency:
- 50/60 Hz
- [Ics] Rated Service Breaking Capacity:
- 100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
- Ambient Air Temperature For Operation:
- -25-70°C
- Continuous Current Rating:
- 0.8
- Product Name:
- PowerPact B
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Electrical Connection:
- I-Line connection, line || lugs, load
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Local Signaling:
- presence of auxiliary contacts flag green)
- Trip Unit Technology:
- thermal-magnetic
- Quantity Per Set:
- set of 1