Schneider Electric

Schneider Electric BJF26030 Circuit breaker, PowerPacT B, 30A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
BJF26030
MPN:
BJF26030
Condition:
New
Awg Gauge:
AWG 14...AWG 8 aluminium/copper || AWG 6...AWG 3/0 aluminium/copper
Connection Pitch:
27 mm
Tightening Torque:
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Continuous Current Rating:
0.8
Control Type:
toggle
Protected Poles Description:
2t
Ip Degree Of Protection:
front cover IP40 IEC 60529
Eu Rohs Directive:
Compliant with Exemptions
Rohs Exemption Information:
Yes
Product Name:
PowerPact B
Circuit Breaker Application:
HACR rated
Suitability For Isolation:
yes IEC 60947-2
Range:
PowerPact
Color:
Gray RAL 7016)
Mercury Free:
Yes
Device Short Name:
BJ 030
Poles Description:
2P
9 Mm Pitches:
6
Line Rated Current:
30-30 A
Ik Degree Of Protection:
IK07 conforming to IEC 62262
Operating Altitude:
6561.68 ft (2000 m) without derating || 5000 m with derating
Standards:
EN/IEC 60947-2 || GB 14048.2 || NMX J-266 || EN/IEC 60947-5-1 || UL 489 || NEMA AB1 || CSA C22.2 No 5
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Width:
54 mm
Breaking Capacity Code:
J
Country of Origin:
Mexico
Device Application:
distribution
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Local Signaling:
presence of auxiliary contacts flag green)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Electrical Connection:
terminal nut, ON and OFF end
Mounting Mode:
clip-on 35 mm symmetrical DIN rail) || by screws plate)
Quality Labels:
CE
Pollution Degree:
3 IEC 60947-1
Mechanical Durability:
15000 cycles IEC 947-1 Annex K ed 5.2
Trip Unit Technology:
thermal-magneticTM-D,
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Pvc Free:
Yes
Net Weight:
0.669 kg
Circularity Profile:
N/A
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Utilisation Category:
category A
Wire Stripping Length:
20 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weight:
0.669 kg
$1,403.00