Schneider Electric

Schneider Electric CAD323FE7 TeSys Deca control relay - 3 NO + 2 NC - <= 690 V - 115 V AC standard coil

(No reviews yet) Write a Review
SKU:
CAD323FE7
MPN:
CAD323FE7
Condition:
New
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
IP2X front face VDE 0106
Weight:
0.58 kg
Control Circuit Type:
AC 50/60 Hz
Depth:
84 mm
[Uc] Control Circuit Voltage:
115 V AC 50/60 Hz
Product Name:
TeSys CAD
Irms Rated Making Capacity:
140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Mercury Free:
Yes
Product Or Component Type:
control relay
Pole Contact Composition:
3 NO + 2 NC
Non-Overlap Time:
1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
Mounting Support:
rail || plate
Inrush Power In Va:
70-70 VA 50 Hz (at 20°C)
Mechanical Durability:
30 Mcycles
Contactor Application:
control circuit
Mechanical Robustness:
shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Hold-In Power Consumption In Va:
8-8 VA 50 Hz (at 20°C)
Eu Rohs Directive:
Compliant with Exemptions
Width:
45 mm
Minimum Switching Current:
5 mA
Ambient Air Temperature For Storage:
-60-80°C
Range:
TeSys || TeSys Deca
Circularity Profile:
ENVEOLI1501004
Protective Treatment:
TH IEC 60068
Operating Time:
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
Net Weight:
0.58 kg
Connections - Terminals:
spring terminals 1 1-2.5 mm²flexible without cable end || spring terminals 2 1-2.5 mm²flexible without cable end || spring terminals 1 1-2.5 mm²solid without cable end || spring terminals 2 1-2.5 mm²solid without cable end
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Country of Origin:
Indonesia
[Ui] Rated Insulation Voltage:
600 V UL || 600 V CSA || 690 V IEC 60947-5-1
Maximum Operating Rate:
180 cyc/mn
Utilisation Category:
AC-15 || DC-13 || AC-14
Device Short Name:
CAD
Warranty:
18 months
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Standards:
EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Product Certifications:
CB || CCC || UL || CSA || EAC || CE || UKCA
Environmental Disclosure:
ENVPEP1501004
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Operating Altitude:
0...9842.52 ft (0...3000 m)
Associated Fuse Rating:
10 A gG conforming to IEC 60947-5-1
$63.25

Description

TeSys D control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 115V 50/60Hz AC control circuit, connection by spring terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).
View AllClose