Schneider Electric

Schneider Electric EDB16040 Mini circuit breaker, E-Frame, 40A, 1 pole, 600Y/347VAC, 25kA max, bolt on

(No reviews yet) Write a Review
SKU:
EDB16040
MPN:
EDB16040
Condition:
New
Trip Unit Rating:
1800-1800 A
Electrical Connection:
lugs aluminium
Line Rated Current:
40 A
Module Type:
E-Frame
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Local Signaling:
trip indicator
Holding Current:
630 A
Circuit Breaker Application:
HACR rated
Number Of Spaces Required:
1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
IEC || cULus
Device Short Name:
EDB
[Ue] Rated Operational Voltage:
600Y/347 V AC
Mercury Free:
Yes
Mounting Mode:
bolt-on
Product Destination:
NF panelboard
Weight:
2 lb(US)
Trip Unit Technology:
thermal-magnetic
Country of Origin:
United States
Net Weight:
2 lb(US)
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Product Or Component Type:
circuit-breaker
Ambient Air Temperature For Operation:
40°C
Protection Type:
overload || short-circuit
Depth:
4.05 in
Rohs Exemption Information:
Yes
Warranty:
18 months
Breaking Capacity:
14 kA 600Y/347 V AC
Breaking Capacity Code:
D
Number Of Poles:
1
Range Of Product:
125 A Frame EDB-EGB-EJB
Number Of Spaces:
1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
$150.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 40A, 1 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose