Schneider Electric

Schneider Electric EDB16045 Mini circuit breaker, E-Frame, 45A, 1 pole, 600Y/347VAC, 25kA max, bolt on

(No reviews yet) Write a Review
SKU:
EDB16045
MPN:
EDB16045
Condition:
New
Protection Type:
short-circuit || overload
Warranty:
18 months
Local Signaling:
trip indicator
Weight:
2 lb(US)
Holding Current:
630 A
Number Of Poles:
1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity Code:
D
Rohs Exemption Information:
Yes
Country of Origin:
United States
Number Of Spaces Required:
1
Depth:
4.05 in
Number Of Spaces:
1
Electrical Connection:
lugs aluminium
Product Destination:
NF panelboard
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Mounting Mode:
bolt-on
[Ue] Rated Operational Voltage:
600Y/347 V AC
Breaking Capacity:
14 kA 600Y/347 V AC
Net Weight:
2 lb(US)
Device Short Name:
EDB
Range Of Product:
125 A Frame EDB-EGB-EJB
Module Type:
E-Frame
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Certifications:
IEC || cULus
Mercury Free:
Yes
Ambient Air Temperature For Operation:
40°C
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Trip Unit Rating:
1800-1800 A
Product Or Component Type:
circuit-breaker
Line Rated Current:
45 A
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Trip Unit Technology:
thermal-magnetic
Circuit Breaker Application:
HACR rated
$150.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 45A, 1 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose