Schneider Electric

Schneider Electric GV4PE07N Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PE07N
MPN:
GV4PE07N
Condition:
New
Environmental Disclosure:
ENVPEP1704004EN
Operating Position:
any position
Net Weight:
1.45 kg
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Or Component Type:
motor circuit breaker
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Pollution Degree:
3
Depth:
116 mm
Trip Unit Technology:
electronic || thermal-magnetic
Color:
Gray RAL 7016)
Pvc Free:
Yes
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Weight:
1.45 kg
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Warranty:
18 months
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Circularity Profile:
ENVEOLI1704004EN
Ambient Air Temperature For Operation:
-25-70°C
Rated Duty:
continuous IEC 60947-4-1
Mechanical Durability:
40000 cycles
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Suitability For Isolation:
yes IEC 60947-1
Fire Resistance:
960°C IEC 60695-2-11
Phase Failure Sensitivity:
yes IEC 60947-4-1
Ik Degree Of Protection:
IK07 IEC 62262
Range Of Product:
TeSys GV4
Width:
81 mm
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Climatic Withstand:
IACS E10
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Line Rated Current:
0.291666666666667
Poles Description:
3P
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Operating Altitude:
5000 m
Mercury Free:
Yes
Ip Degree Of Protection:
IP40 IEC 60529
Halogen Content Performance:
Halogen free plastic parts product
Country of Origin:
Poland
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Ambient Air Temperature For Storage:
-50-85°C
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Motor Power Kw:
1.5-1.5 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 400...415 V AC 50/60 Hz || 2.5-2.5 kW 400...415 V AC 50/60 Hz || 3-3 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 500 V AC 50/60 Hz || 2.5-2.5 kW 500 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500
Power Dissipation Per Pole:
4.6 W
Device Short Name:
GV4PE
Product Name:
TeSys GV4 || TeSys Deca
Magnetic Tripping Current:
119-119 A
$695.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 2.9-7A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose