Schneider Electric

Schneider Electric GV4PE80B Motor circuit breaker, TeSys GV4, 3P, 80A, Icu 25kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PE80B
MPN:
GV4PE80B
Condition:
New
Device Application:
motor protection
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Halogen Content Performance:
Halogen free plastic parts product
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Range Of Product:
TeSys GV4
Poles Description:
3P
Mercury Free:
Yes
Trip Unit Technology:
thermal-magnetic || electronic
Pollution Degree:
3
Breaking Capacity:
50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 35 kA 208Y/120 V AC 50/60 Hz UL 60947 || 35 kA 240 V AC 50/60 Hz U
Operating Altitude:
5000 m
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Suitability For Isolation:
yes IEC 60947-1
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Line Rated Current:
80 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
1.45 kg
Pvc Free:
Yes
Product Name:
TeSys GV4 || TeSys Deca
Ik Degree Of Protection:
IK07 IEC 62262
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 30-30 kW 500 V AC 50/60 Hz || 37-37 kW 660...690 V AC 50/60 Hz || 45-45 kW 660...690 V AC 50/60 Hz || 55-55 kW 660...690 V AC 50/60 Hz || 30-30 kW 4
Power Dissipation Per Pole:
4.6 W
Rated Duty:
continuous IEC 60947-4-1
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Maximum Operating Rate:
25 cyc/h
Ambient Air Temperature For Storage:
-50-85°C
Magnetic Tripping Current:
1360-1360 A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Environmental Disclosure:
ENVPEP1704004EN
Rohs Exemption Information:
Yes
Range:
TeSys Deca
Country of Origin:
France
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Electrical Durability:
14000 cycles AC-3 440 V In/2 || 7000 cycles AC-3 440 V In
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Mechanical Durability:
40000 cycles
Ip Degree Of Protection:
IP40 IEC 60529
Fire Resistance:
960°C IEC 60695-2-11
Circularity Profile:
ENVEOLI1704004EN
Ambient Air Temperature For Operation:
-25-70°C
Depth:
116 mm
Warranty:
18 months
$695.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 25kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 40-80A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose