Schneider Electric HJL36050M72BC Motor Circuit Protector 600V 50A

(No reviews yet) Write a Review
SKU:
HJL36050M72BC
UPC:
785901437543
Condition:
New
Terminal Identifier:
AL150HD
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quality Labels:
CE
Width:
104 mm
Magnetic Tripping Current:
84-546 A
Environmental Disclosure:
ENVPEP2206027EN
Color:
Black
Pvc Free:
Yes
Product Name:
PowerPact H
Electrical Connection:
lugs, line || lugs, load
Mercury Free:
Yes
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
[Ith] Conventional Free Air Thermal Current:
14-42 A
Eu Rohs Directive:
Compliant with Exemptions
Mounting Support:
lug
Quantity Per Set:
1
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Control Type:
toggle
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ip Degree Of Protection:
front cover IP40 IEC 60529
Range:
PowerPact
Pollution Degree:
3 IEC 60947-1
Product Or Component Type:
Motor Circuit Protector
Wire Stripping Length:
16 mm
Ambient Air Temperature For Storage:
-50-85 °C
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Network Frequency:
50/60 Hz
Warranty:
18 months
Mounting Mode:
unit mount lug)
Height:
163 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Protected Poles Description:
3t
Accessory / Separate Part Type:
alarm switch 24 V AC/DC 1 NO + 1 NC cover frame
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Depth:
86 mm
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Breaking Capacity Code:
J
Ambient Air Temperature For Operation:
-2-70 °C
Communication Interface:
Modbus || Ethernet
Sustainable Offer Status:
Green Premium product
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Continuous Current Rating:
0.8
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Rohs Exemption Information:
Yes
Utilisation Category:
category A
Line Rated Current:
50-50 A
Device Application:
distribution
Product Certifications:
UL || CSA || NOM
Suitability For Isolation:
yes IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Circularity Profile:
ENVEOLI2206027EN
Net Weight:
2.2 kg
Poles Description:
3P
Brochure:
View
Catalog:
View
Datasheet:
View
$1,682.00

Description

PowerPacT H-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. This PowerPacT H, 50A, 3 pole, motor protector has a breaking capacity of 25kA at 600VAC. This unit has lugs on both the line and load side. These motor protectors accept the same accessories and terminals as PowerPacT H circuit breakers. This breaker has a continuous current rating of 80%. This unit includes an alarm switch. PowerPacT H motor circuit protectors comply to UL, CSA, and IEC standards and are CE marked.
View AllClose