- Sustainable Offer Status:
- Green Premium product
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Ambient Air Temperature For Operation:
- -2-70 °C
- Circularity Profile:
- ENVEOLI2206031EN
- Utilisation Category:
- category A
- Net Weight:
- 2.4 kg
- Ip Degree Of Protection:
- front cover IP40
- Breaking Capacity Code:
- D
- Terminal Identifier:
- AL250JD
- Trip Unit Technology:
- thermal-magnetic
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Height:
- 191 mm
- Magnetic Tripping Current:
- 2250-2250 A
- Quality Labels:
- CE
- Product Or Component Type:
- circuit breaker
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Electrical Connection:
- I-Line connection, line || lugs, load
- Width:
- 104 mm
- Wire Stripping Length:
- 25 mm
- Communication Interface:
- Modbus
- Depth:
- 86 mm
- Mounting Height:
- 4.5 in
- Warranty:
- 18 months
- Suitability For Isolation:
- yes IEC 60947-2
- Continuous Current Rating:
- 0.8
- Circuit Breaker Application:
- HACR rated
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Environmental Disclosure:
- ENVPEP2206031EN
- Poles Description:
- 2P
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Product Certifications:
- UL || CSA || NOM
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Storage:
- -50-85 °C
- Network Frequency:
- 50/60 Hz
- Mercury Free:
- Yes
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Phase Connection:
- BC
- Pollution Degree:
- 3
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Line Rated Current:
- 225-225 A
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mounting Support:
- bracket
- Protection Type:
- overload protection || short-circuit protection
- Magnetic Hold Current:
- 1125 A
- Eu Rohs Directive:
- Compliant with Exemptions
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Pvc Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Mounting Mode:
- I-Line bracket)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Control Type:
- toggle
- QN-QUOTE-REQUEST:
- true