Schneider Electric

Schneider Electric LADR06 Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 0.3-3s, front, lugs-ring terminals

(No reviews yet) Write a Review
SKU:
LADR06
MPN:
LADR06
Condition:
New
Auxiliary Contacts Operation:
time delay
Circularity Profile:
N/A
Range Compatibility:
TeSys D CAD || TeSys D LC1D || TeSys F LC1F || TeSys F CR1F || TeSys Deca CAD || TeSys Deca LC1D
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Non-Overlap Time:
1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
Tightening Torque:
1.7 N.m flat Ø 6 mm || 1.7 N.m Philips No 2 || 1.7 N.m pozidriv No 2
Pvc Free:
Yes
Environmental Characteristic:
normal environment
Connections - Terminals:
lugs-ring terminals 8 mm)
Timer Type:
off delay
Standards:
EN/IEC 60947-5-1 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.5 || EN 50012 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
[Ue] Rated Operational Voltage:
690 V AC 25...400 Hz
Time Delay Range:
0.3...3 s
Mechanical Durability:
5 Mcycles
California Proposition 65:
WARNING: Cancer - www.P65Warnings.ca.gov
[Ie] Rated Operational Current:
6 A at 120 V AC-15 || 1.04 A at 690 V AC-15 || 0.55 A at 125 V DC-13 || 0.1 A at 600 V DC-13
Range:
TeSys || TeSys Deca
Warranty:
18 months
Operating Altitude:
9842.52 ft (3000 m)
[Ui] Rated Insulation Voltage:
690 V IEC 60947-5-1 || 600 V UL 60947-5-1 || 600 V CSA C22.2 No 60947-5-1
Product Name:
TeSys Deca
Mounting Location:
front
Width:
44 mm
Product Or Component Type:
time delay auxiliary contact block
Sustainable Offer Status:
Green Premium product
Pole Contact Composition:
1 NO + 1 NC
Eu Rohs Directive:
Compliant with Exemptions
Minimum Switching Current:
5 mA
Mercury Free:
Yes
Insulation Resistance:
> 10 MOhm
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Color:
dark grey
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Sustainable Packaging:
Yes
Minimum Switching Voltage:
17 V
Protection Type:
gG fuse 10 A
Ambient Air Temperature For Operation:
-40-70°C
Rohs Exemption Information:
Yes
Country of Origin:
France
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP110702EN_V01
Permissible Short-Time Rating:
100 A 60°C 1 s || 120 A 60°C 500 ms || 140 A 60°C 100 ms
Protective Treatment:
TH IEC 60068
Irms Rated Making Capacity:
140 A AC || 250 A DC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
IECEE CB Scheme || UL || CSA || CCC || EAC || UKCA
Depth:
61 mm
Ambient Air Temperature For Storage:
-60-80°C
$157.20

Description

TeSys Deca time delay auxiliary contact block, for contactors LC1D and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, Off-delay setting range 0.3-3s, connection by lugs-ring terminals. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).
View AllClose