Schneider Electric LC1D129SD IEC contactor, TeSys D, nonreversing, 12A, 7.5HP at 480VAC, 3 phase, 3 pole, 3 NO, 72VDC coil, open style
Schneider Electric
$149.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Plug-in connectors are used for the load connections and Faston terminals for the control circuit. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.07 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Control Circuit Type:
- DC standard
- [Ith] Conventional Free Air Thermal Current:
- 25 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- Maximum Horse Power Rating:
- 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase
- Product Or Component Type:
- contactor
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Depth:
- 95 mm
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Pvc Free:
- Yes
- Weight:
- 0.485 kg
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Pole Contact Composition:
- 3 NO
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Electrical Durability:
- 2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
- Rohs Exemption Information:
- Yes
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Connections - Terminals:
- control circuit: Faston terminals 1 || power circuit: plug-in connector
- Signaling Circuit Frequency:
- 25...400 Hz
- Power Dissipation Per Pole:
- 0.36 W AC-3 || 1.56 W AC-1 || 0.36 W AC-3e
- Overvoltage Category:
- III
- [Ie] Rated Operational Current:
- 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Flame Retardance:
- V1 conforming to UL 94
- Product Certifications:
- RINA || CCC || GL || BV || UL || LROS (Lloyds register of shipping) || CSA || DNV || GOST || UKCA
- Sustainable Offer Status:
- Green Premium product
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Fire Resistance:
- 850°C IEC 60695-2-1
- Poles Description:
- 3P
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Time Constant:
- 28 ms
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Utilisation Category:
- AC-3 || AC-1 || AC-4 || AC-3e
- Range Of Product:
- TeSys Deca
- Hold-In Power Consumption In W:
- 5.4-5.4 W 20°C
- Width:
- 45 mm
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Warranty:
- 18 months
- Protective Treatment:
- THIEC 60068-2-30
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1