Schneider Electric

Schneider Electric LC1D258FD IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 2 NO and 2 NC, 110VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D258FD
MPN:
LC1D258FD
Condition:
New
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Mercury Free:
Yes
Electrical Durability:
1.4 Mcycles 40 A AC-1 <= 440 V
Rohs Exemption Information:
Yes
Signaling Circuit Frequency:
25...400 Hz
Inrush Power In W:
5.4-5.4 W 20°C)
Depth:
107 mm
Pollution Degree:
3
Time Constant:
28 ms
Range Of Product:
TeSys Deca
Product Or Component Type:
contactor
Eu Rohs Directive:
Compliant with Exemptions
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Ip Degree Of Protection:
IP20 front face IEC 60529
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamps terminals flat Ø 6 mm || po
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Warranty:
18 months
Circularity Profile:
ENVEOLI1102030EN
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Net Weight:
0.585 kg
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Device Short Name:
LC1D
Overvoltage Category:
III
Hold-In Power Consumption In W:
5.4-5.4 W 20°C
Control Circuit Type:
DC standard
Operating Time:
63±15 % ms closing || 20±20 % ms opening
Mechanical Durability:
30 Mcycles
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Protective Treatment:
THIEC 60068-2-30
Minimum Switching Current:
5 mA for Signaling circuit
Poles Description:
4P
Pole Contact Composition:
2 NO + 2 NC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Icw] Rated Short-Time Withstand Current:
240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Uc] Control Circuit Voltage:
110 V DC
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Compatibility Code:
LC1D
Mounting Support:
rail || plate
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Country of Origin:
Singapore
Operating Altitude:
0...9842.52 ft (0...3000 m)
Contactor Application:
resistive load
Auxiliary Contact Composition:
1 NO + 1 NC
$255.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 110 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.13 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose