Schneider Electric

Schneider Electric LC1D258P7 IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D258P7
MPN:
LC1D258P7
Condition:
New
Compatibility Code:
LC1D
Power Dissipation Per Pole:
3.2 W AC-1
Flame Retardance:
V1 conforming to UL 94
Sustainable Offer Status:
Green Premium product
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Poles Description:
4P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Type:
AC 50/60 Hz
Mechanical Durability:
15 Mcycles
Overvoltage Category:
III
Eu Rohs Directive:
Compliant
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Fire Resistance:
850°C IEC 60695-2-1
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Net Weight:
0.425 kg
Warranty:
18 months
Insulation Resistance:
> 10 MOhm for Signaling circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Product Certifications:
UL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL
Signaling Circuit Frequency:
25...400 Hz
Country of Origin:
Indonesia
Mounting Support:
plate || rail
Auxiliary Contact Composition:
1 NO + 1 NC
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Contactor Application:
resistive load
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Minimum Switching Current:
5 mA for Signaling circuit
Minimum Switching Voltage:
17 V for Signaling circuit
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Rohs Exemption Information:
Yes
Electrical Durability:
1.4 Mcycles 40 A AC-1 <= 440 V
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Heat Dissipation:
2-3 W at 50/60 Hz
Device Short Name:
LC1D
Operating Time:
12...22 ms closing || 4...19 ms opening
Range Of Product:
TeSys Deca
[Icw] Rated Short-Time Withstand Current:
240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
$246.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.13 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose