Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Depth:
101 mm
Average Impedance:
2 mOhm - Ith 50 A 50 Hz for power circuit
Net Weight:
0.54 kg
Product Or Component Type:
contactor
Signaling Circuit Frequency:
25...400 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pole Contact Composition:
3 NO
Operating Altitude:
0...9842.52 ft (0...3000 m)
Flame Retardance:
V1 conforming to UL 94
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Pollution Degree:
3
Inrush Power In W:
5.4-5.4 W 20°C)
Warranty:
18 months
Pvc Free:
Yes
Power Dissipation Per Pole:
5 W AC-1 || 3 W AC-3 || 3 W AC-3e
Contactor Application:
motor control || resistive load
Product Certifications:
UL || DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || GOST || CSA || BV
Minimum Switching Current:
5 mA for Signaling circuit
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4 || power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4 |
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 50 A (at 60°C) for power circuit
Rated Breaking Capacity:
550 A at 440 V for power circuit conforming to IEC 60947
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Compatibility Code:
LC1D
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Protective Treatment:
THIEC 60068-2-30
Country of Origin:
Indonesia
Poles Description:
3P
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contact Composition:
1 NO + 1 NC
Time Constant:
28 ms
Minimum Switching Voltage:
17 V for Signaling circuit
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
Mechanical Durability:
30 Mcycles
Overvoltage Category:
III
Electrical Durability:
1.4 Mcycles 50 A AC-1 <= 440 V || 1.4 Mcycles 38 A AC-3 <= 440 V || 1.4 Mcycles 38 A AC-3e <= 440 V
[Uc] Control Circuit Voltage:
36 V DC
Maximum Horse Power Rating:
10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 5 hp at 240 V AC 50/60 Hz for 1 phase motors || 20 hp at 480 V AC 50/60 Hz for 3 phase motors || 25 hp at 600 V AC 50/60 Hz for 3 phase motors
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Control Circuit Type:
DC standard
Circularity Profile:
ENVEOLI1102030EN
$241.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 38A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 25HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 36 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.