Schneider Electric

Schneider Electric LC1D38F7 IEC contactor, TeSys Deca, nonreversing, 38A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D38F7
MPN:
LC1D38F7
Condition:
New
Range:
TeSys || TeSys Deca
Eu Rohs Directive:
Compliant
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || contro
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Net Weight:
0.38 kg
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
Environmental Disclosure:
ENVPEP110229EN
Height:
85 mm
Weight:
0.38 kg
[Ie] Rated Operational Current:
50 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 38 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Flame Retardance:
V1 conforming to UL 94
Rohs Exemption Information:
Yes
Mounting Support:
plate || rail
Depth:
92 mm
Auxiliary Contact Composition:
1 NO + 1 NC
Motor Power Kw:
18.5 kW at 500 V AC 50/60 Hz || 18.5 kW at 660...690 V AC 50/60 Hz || 18.5 kW at 380...400 V AC 50/60 Hz || 9 kW at 220...230 V AC 50/60 Hz || 18.5 kW at 415...440 V AC 50/60 Hz
Minimum Switching Current:
5 mA for Signaling circuit
Coil Technology:
without built-in suppressor module
Mechanical Durability:
15 Mcycles
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Ip Degree Of Protection:
IP20 front face IEC 60529
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Insulation Resistance:
> 10 MOhm for Signaling circuit
Fire Resistance:
850°C IEC 60695-2-1
Protective Treatment:
THIEC 60068-2-30
Country of Origin:
France
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Circularity Profile:
ENVEOLI110229EN
Contactor Application:
resistive load || motor control
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
Poles Description:
3P
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Operating Altitude:
0...9842.52 ft (0...3000 m)
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Control Circuit Type:
AC 50/60 Hz
Overvoltage Category:
III
Minimum Switching Voltage:
17 V for Signaling circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Warranty:
18 months
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
$231.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 38A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 25HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.84 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose