Schneider Electric LC1D40008P7 IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
Schneider Electric
$496.80
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 230 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 4.92 inches deep. It weighs 3.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hex
- Protective Treatment:
- THIEC 60068-2-30
- Mounting Support:
- plate || rail
- Irms Rated Making Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Mercury Free:
- Yes
- Pollution Degree:
- 3
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-55°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 0.85...1.1 Uc -40-55°C operational AC 60 Hz
- Rohs Exemption Information:
- Yes
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- [Ue] Rated Operational Voltage:
- power circuit <= 1000 V AC 25...400 Hz
- Poles Description:
- 4P
- Depth:
- 125 mm
- Mechanical Durability:
- 6 Mcycles
- Reach Free Of Svhc:
- Yes
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Device Short Name:
- LC1D
- [Ie] Rated Operational Current:
- 60 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Eu Rohs Directive:
- Compliant
- Power Dissipation Per Pole:
- 5.4 W AC-1
- Contactor Application:
- resistive load
- Electrical Durability:
- 1.4 Mcycles 60 A AC-1 <= 440 V
- Warranty:
- 18 months
- Country of Origin:
- Czechia
- Width:
- 85 mm
- Weight:
- 1.44 kg
- Fire Resistance:
- 850°C IEC 60695-2-1
- Range Of Product:
- TeSys Deca
- Compatibility Code:
- LC1D
- Sustainable Offer Status:
- Green Premium product
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Control Circuit Type:
- AC 50/60 Hz
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Associated Fuse Rating:
- 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
- Standards:
- EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
- Climatic Withstand:
- IACS E10 exposure to damp heat
- Average Impedance:
- 1.5 mOhm - Ith 60 A 50 Hz for power circuit
- [Icw] Rated Short-Time Withstand Current:
- 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit
- Inrush Power In Va:
- 245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
- Product Or Component Type:
- contactor
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- Product Certifications:
- UL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL
- [Ith] Conventional Free Air Thermal Current:
- 60 A (at 60°C) for power circuit
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
- Maximum Operating Rate:
- 3600 cyc/h 60°C