Schneider Electric LC1D40AL7 IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 200VAC 50/60Hz coil, open
Schneider Electric
$261.60
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 200 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Weight:
- 0.85 kg
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
- Protective Treatment:
- THIEC 60068-2-30
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
- Depth:
- 120 mm
- Motor Power Kw:
- 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 11 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 415...440 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 9 kW at 400 V AC 50/60 Hz (AC-4) || 18.
- Pollution Degree:
- 3
- Warranty:
- 18 months
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- Compatibility Code:
- LC1D
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Heat Dissipation:
- 4-5 W at 50/60 Hz
- Overvoltage Category:
- III
- [Uc] Control Circuit Voltage:
- 200 V AC 50/60 Hz
- Height:
- 122 mm
- Environmental Disclosure:
- ENVPEP1503009EN
- Electrical Durability:
- 1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
- Width:
- 55 mm
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
- Mechanical Durability:
- 6 Mcycles
- Device Short Name:
- LC1D
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Average Impedance:
- 1.5 mOhm - Ith 60 A 50 Hz for power circuit
- Mounting Support:
- plate || rail
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Toxic Heavy Metal Free:
- Yes
- Standards:
- EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Net Weight:
- 0.85 kg
- Coil Technology:
- without built-in suppressor module
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Product Or Component Type:
- contactor
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Contactor Application:
- resistive load || motor control
- Circularity Profile:
- ENVEOLI1503009EN
- Maximum Horse Power Rating:
- 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 115 V AC 50/60 Hz for 1 phase m
- Reach Free Of Svhc:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Protective Cover:
- with
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Signaling Circuit Frequency:
- 25...400 Hz