Schneider Electric LC1D80AEHE IEC contactor, TeSys Deca Green, nonreversing, 80A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 48/130VAC/VDC coil, open style
Schneider Electric
$444.00
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 40HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Utilisation Category:
- AC-3 || AC-1 || AC-3e
- Flame Retardance:
- V1 conforming to UL 94
- Maximum Horse Power Rating:
- 5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp
- Height:
- 122 mm
- Mounting Support:
- plate || rail
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Associated Fuse Rating:
- 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
- Power Dissipation Per Pole:
- 9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Overvoltage Category:
- III
- Device Short Name:
- LC1D
- Connections - Terminals:
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
- Mechanical Durability:
- 6 Mcycles
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Depth:
- 120 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Hold-In Power Consumption In Va:
- 1.4-1.4 VA 50/60 Hz (at 20°C)
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC-1 for power circuit || 66 A (at <60°C) at <= 440 V AC-3 for power circuit || 66 A (at <60°C) at <= 440 V AC-3e for power circuit
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Warranty:
- 18 months
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Environmental Disclosure:
- ENVPEP1607010EN
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Rohs Exemption Information:
- Yes
- Electrical Durability:
- 1 Mcycles 66 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1 Mcycles 66 A AC-3e <= 440 V
- Poles Description:
- 3P
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Icw] Rated Short-Time Withstand Current:
- 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 640 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- Contactor Application:
- motor control || resistive load
- Control Circuit Voltage Limits:
- <= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
- Compatibility Code:
- LC1D
- Range Of Product:
- TeSys Deca
- Pole Contact Composition:
- 3 NO
- [Ith] Conventional Free Air Thermal Current:
- 80 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
- [Uc] Control Circuit Voltage:
- 48...130 V AC 50/60 Hz || 48...130 V DC
- Weight:
- 1.002 kg
- Heat Dissipation:
- 0.9-0.9 W at 50/60 Hz
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
- Signaling Circuit Frequency:
- 25...400 Hz
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Circularity Profile:
- ENVEOLI1607010EN
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Country of Origin:
- France
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Sustainable Offer Status:
- Green Premium product