TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 125 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.58 inches tall, 1.77 inches wide and 4.21 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Contactor Application:
- resistive load
- Range:
- TeSys || TeSys Deca
- Overvoltage Category:
- III
- Flame Retardance:
- V1 conforming to UL 94
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Warranty:
- 18 months
- Connections - Terminals:
- control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 8 mm
- Device Short Name:
- LC1D
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Pole Contact Composition:
- 4 NO
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Average Impedance:
- 2 mOhm - Ith 40 A 50 Hz for power circuit
- Signaling Circuit Frequency:
- 25...400 Hz
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
- Tightening Torque:
- control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || control circuit 1.7 N.m lugs-ring terminals pozidriv No 2 M3.5 || power circuit 1.8 N.m lugs-ring terminals flat Ø 6 mm
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Protective Treatment:
- THIEC 60068-2-30
- Range Of Product:
- TeSys Deca
- Coil Technology:
- built-in bidirectional peak limiting diode suppressor
- Sustainable Offer Status:
- Green Premium product
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Power Dissipation Per Pole:
- 3.2 W AC-1
- Weight:
- 0.425 kg
- Inrush Power In W:
- 5.4-5.4 W 20°C)
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Rohs Exemption Information:
- Yes
- [Icw] Rated Short-Time Withstand Current:
- 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Time Constant:
- 28 ms
- Mercury Free:
- Yes
- Pollution Degree:
- 3
- Environmental Disclosure:
- ENVPEP110230EN
- Eu Rohs Directive:
- Compliant
- Electrical Durability:
- 1.4 Mcycles 40 A AC-1 <= 440 V
- Country of Origin:
- France
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Product Or Component Type:
- contactor
- Net Weight:
- 0.425 kg
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC