Schneider Electric LC1G115EHEA Contactor, high power, TeSys Giga, advanced version, AC-3, <= 440V, 115A, 3 pole/NO, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G115EHEA
MPN:
LC1G115EHEA
Condition:
New
Operating Time:
40...70 ms closing || 15...50 ms opening
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Inrush Power In W:
190 W
Auxiliary Contact Composition:
1 NO + 1 NC
Product Or Component Type:
contactor
Inrush Power In Va:
260-260 VA
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
[Ie] Rated Operational Current:
250 A (at <40°C) at <= 1000 V AC-1 || 115 A (at <60°C) at <= 440 V AC-3
[Ith] Conventional Free Air Thermal Current:
250 A (at 40°C)
Color:
dark grey
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Average Impedance:
0.00018 Ohm
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Mechanical Durability:
8 Mcycles
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Eu Rohs Directive:
Compliant with Exemptions
Mercury Free:
Yes
Width:
108 mm
[Icw] Rated Short-Time Withstand Current:
1.1 kA - 10 s || 0.64 kA - 30 s || 0.52 kA - 1 min || 0.4 kA - 3 min || 0.32 kA - 10 min
China Rohs Regulation:
X
Motor Power Kw:
30 kW at 230 V AC 50/60 Hz (AC-3e) || 55 kW at 400 V AC 50/60 Hz (AC-3e) || 55 kW at 415 V AC 50/60 Hz (AC-3e) || 75 kW at 440 V AC 50/60 Hz (AC-3e) || 75 kW at 500 V AC 50/60 Hz (AC-3e) || 75 kW at 690 V AC 50/60 Hz (AC-3e) || 30 kW at 230 V AC 50/6
Power Dissipation Per Pole:
10 W AC-1 - Ith 250 A || 3 W AC-3 - Ith 115 A
[Ui] Rated Insulation Voltage:
1000 V
Rated Breaking Capacity:
1040 A at 440 V
Weight:
4.1 kg
Country of Origin:
China
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Coil Technology:
built-in bidirectional peak limiting
Ambient Air Temperature For Operation:
-25-60°C
Irms Rated Making Capacity:
1560 A at 440 V
Net Weight:
4.1 kg
Pvc Free:
Yes
Hold-In Power Consumption In Va:
8.9-8.9 VA
Hold-In Power Consumption In W:
5.0-5.0 W
Rohs Exemption Information:
Yes
Connection Pitch:
35 mm
Ambient Air Temperature For Storage:
-60-80°C
Contactor Application:
power switching || motor control
Protective Treatment:
TH
Tightening Torque:
18 N.m
Sustainable Offer Status:
Green Premium product
Device Short Name:
LC1G
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
Height:
255 mm
Depth:
193 mm
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Mounting Support:
plate
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Range Of Product:
TeSys Giga
$750.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 115A 75kW@440V. It provides a 48-130V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.