Schneider Electric

Schneider Electric LC1G1504LSEA Contactor, high power, TeSys Giga, advanced version, 4 pole/NO, AC-1 <=440V 275A, 200-500VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G1504LSEA
MPN:
LC1G1504LSEA
Condition:
New
Hold-In Power Consumption In W:
8.0-8.0 W
Color:
dark grey
Range:
TeSys
Hold-In Power Consumption In Va:
13.0-13.0 VA
Rohs Exemption Information:
Yes
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Coil Technology:
built-in bidirectional peak limiting
Mounting Support:
plate
Tightening Torque:
18 N.m
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
5.1 kg
Overvoltage Category:
III
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 25 x 6 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Range Of Product:
TeSys Giga
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
[Uc] Control Circuit Voltage:
200...500 V AC 50/60 Hz || 200...500 V DC
Pvc Free:
Yes
[Icw] Rated Short-Time Withstand Current:
1.2 kA - 10 s || 0.7 kA - 30 s || 0.6 kA - 1 min || 0.45 kA - 3 min || 0.35 kA - 10 min
Ambient Air Temperature For Storage:
-60-80°C
Device Short Name:
LC1G
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
[Ith] Conventional Free Air Thermal Current:
275 A (at 40°C)
Poles Description:
4P
Rated Breaking Capacity:
1280 A at 440 V
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Irms Rated Making Capacity:
1890 A at 440 V
Height:
255 mm
China Rohs Regulation:
X
Connection Pitch:
35 mm
Auxiliary Contact Composition:
1 NO + 1 NC
Compatibility Code:
LC1G
Contactor Application:
power switching
Power Dissipation Per Pole:
10 W AC-1 - Ith 275 A || 5 W AC-3 - Ith 150 A
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Mechanical Durability:
8 Mcycles
Circularity Profile:
ENVEOLI2105013
Pole Contact Composition:
4 NO
Inrush Power In Va:
295-295 VA
Country of Origin:
China
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Product Or Component Type:
contactor
Protective Treatment:
TH
Inrush Power In W:
215 W
Halogen Content Performance:
Halogen free plastic parts product
$1,110.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 275A @440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 143mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose