Schneider Electric

Schneider Electric LC1G3304BEEA Contactor, high power, TeSys Giga, advanced version, AC-1, <= 440V, 440A, 4 pole/NO, 24-48VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G3304BEEA
MPN:
LC1G3304BEEA
Condition:
New
Tightening Torque:
35 N.m
Poles Description:
4P
[Icw] Rated Short-Time Withstand Current:
2.65 kA - 10 s || 1.8 kA - 30 s || 1.3 kA - 1 min || 0.9 kA - 3 min || 0.75 kA - 10 min
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
Pole Contact Composition:
4 NO
Product Or Component Type:
contactor
Environmental Disclosure:
ENVPEP2105013
Range:
TeSys
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
Ambient Air Temperature For Operation:
-25-60°C
[Ie] Rated Operational Current:
330 A (at <60°C) at <= 440 V AC-3 || 440 A (at <40°C) at <= 1000 V AC-1
Inrush Power In Va:
540-540 VA
Power Dissipation Per Pole:
30 W AC-1 - Ith 440 A || 16 W AC-3 - Ith 330 A
Hold-In Power Consumption In W:
6.4-6.4 W
Coil Technology:
built-in bidirectional peak limiting
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Pvc Free:
Yes
Halogen Content Performance:
Halogen free plastic parts product
Auxiliary Contact Composition:
1 NO + 1 NC
Mounting Support:
plate
Net Weight:
8.7 kg
Connection Pitch:
45 mm
Range Of Product:
TeSys Giga
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-5a || AC-5b || AC-6a || AC-6b || DC-1 || DC-3 || DC-5
Compatibility Code:
LC1G
[Ui] Rated Insulation Voltage:
1000 V
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Operating Time:
40...70 ms closing || 15...50 ms opening
Weight:
8.7 kg
Mechanical Durability:
8 Mcycles
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
[Uc] Control Circuit Voltage:
24...48 V AC 50/60 Hz || 24...48 V DC
Inrush Power In W:
380 W
Associated Fuse Rating:
400 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 500 A gG at <= 690 V
Average Impedance:
0.000144 Ohm
Irms Rated Making Capacity:
1560 A at 440 V
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Rohs Exemption Information:
Yes
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Color:
dark grey
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Rated Breaking Capacity:
2940 A at 440 V
Circularity Profile:
ENVEOLI2105013
Contactor Application:
power switching
Country of Origin:
China
Height:
290 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
$2,240.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 440A @440V. It provides a 24-48V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose