Schneider Electric

Schneider Electric LC1K06015B7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NC aux., 24VAC coil

(No reviews yet) Write a Review
SKU:
LC1K06015B7
MPN:
LC1K06015B7
Condition:
New
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Range:
TeSys
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Insulation Resistance:
> 10 MOhm for Signaling circuit
Pole Contact Composition:
3 NO
Sustainable Offer Status:
Green Premium product
Depth:
57 mm
Mechanical Durability:
10 Mcycles
Device Application:
control
Auxiliary Contact Composition:
1 NC
Auxiliary Contacts Type:
instantaneous 1 NC
Non Overlap Distance:
0.5 mm
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Heat Dissipation:
1.3-1.3 W
Mercury Free:
Yes
Product Or Component Type:
contactor
Mounting Support:
printed circuit boards
Signaling Circuit Frequency:
<= 400 Hz
Inrush Power In Va:
30-30 VA (at 20°C)
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Control Circuit Type:
AC 50/60 Hz
Connections - Terminals:
solder pins 0.035 mm)
Circularity Profile:
ENVEOLI1503003EN
Poles Description:
3P
Warranty:
18 months
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Ip Degree Of Protection:
IP2X VDE 0106
Operating Altitude:
6561.68 ft (2000 m) without derating
Environmental Disclosure:
ENVPEP1503003EN
Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Toxic Heavy Metal Free:
Yes
Net Weight:
0.18 kg
Ambient Air Temperature For Storage:
-50-80°C
Maximum Operating Rate:
3600 cyc/h
Contactor Application:
motor control
Overvoltage Category:
III
Eu Rohs Directive:
Compliant
$57.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides a 24V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by solder pins for printed circuit boards. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose