Schneider Electric

Schneider Electric LC2D09BL TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V low consumption DC coil

(No reviews yet) Write a Review
SKU:
LC2D09BL
MPN:
LC2D09BL
Condition:
New
Operating Time:
65.45...88.55 ms closing || 20...30 ms opening
Interlocking Type:
mechanical
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Mercury Free:
Yes
Control Circuit Type:
DC low consumption
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Product Or Component Type:
reversing contactor
Circularity Profile:
ENVEOLI1102030EN
Maximum Horse Power Rating:
0.5 hp at 115 V AC 60 Hz for 1 phase motors || 1 hp at 230/240 V AC 60 Hz for 1 phase motors || 2 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 230/240 V AC 60 Hz for 3 phase motors || 5 hp at 460/480 V AC 60 Hz for 3 phase motors || 7.5 hp
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Protective Treatment:
TH IEC 60068-2-30
Motor Power Kw:
2.2 kW at 220...230 V AC 50-60 Hz || 4 kW at 380...400 V AC 50-60 Hz || 4 kW at 415 V AC 50-60 Hz || 4 kW at 440 V AC 50-60 Hz || 5.5 kW at 500 V AC 50-60 Hz || 5.5 kW at 660...690 V AC 50-60 Hz
Minimum Switching Voltage:
17 V for Signaling circuit
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Range:
TeSys || TeSys Deca
Protective Cover:
with
Eu Rohs Directive:
Compliant with Exemptions
Depth:
95 mm
Mechanical Durability:
30 Mcycles
Poles Description:
3P
Height:
77 mm
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Connections - Terminals:
power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp
Mounting Support:
rail || plate
Warranty:
18 months
Rohs Exemption Information:
Yes
Toxic Heavy Metal Free:
Yes
Electrical Durability:
0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V || 2 Mcycles 9 A AC-3e <= 440 V
Signaling Circuit Frequency:
25...400 Hz
[Icw] Rated Short-Time Withstand Current:
30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Width:
90 mm
Ambient Air Temperature For Storage:
-60-80°C
Country of Origin:
France
Overvoltage Category:
III
[Uc] Control Circuit Voltage:
24 V DC
Weight:
1.017 kg
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Pvc Free:
Yes
Associated Fuse Rating:
25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Utilisation Category:
AC-3 || AC-1 || AC-3e
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pole Contact Composition:
3 NO
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Pollution Degree:
3
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
$364.20

Description

TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides low consumption 24V DC coils with transient suppressor module, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose