Schneider Electric

Schneider Electric LC2D09BNE TeSys Deca reversing contactor - 3P - <= 440 V - 9 A AC-3 - 24...60 V AC/DC coil

(No reviews yet) Write a Review
SKU:
LC2D09BNE
MPN:
LC2D09BNE
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Eu Rohs Directive:
Compliant with Exemptions
Protective Treatment:
TH IEC 60068-2-30
Connections - Terminals:
power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp
Product Name:
Tesys Deca green || TeSys Deca
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC || 0.8...1.1 Uc -40-60°C operational DC || 1...1.1 Uc 60-70°C operational AC/DC
Halogen Content Performance:
Halogen free plastic parts & cables product
Overvoltage Category:
III
Minimum Switching Current:
5 mA for Signaling circuit
Pole Contact Composition:
3 NO
Control Circuit Type:
AC 50/60 Hz AC/DC electronic || DC AC/DC electronic
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Poles Description:
3P
Mounting Support:
rail || plate
Operating Time:
45...55 ms closing || 20...90 ms opening
Inrush Power In Va:
15-15 VA 50/60 Hz 20°C)
Rohs Exemption Information:
Yes
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Fire Resistance:
850°C IEC 60695-2-1
Color:
Gray SE GREY 6) || Green SE GREEN 2)
Signaling Circuit Frequency:
25...400 Hz
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Depth:
86 mm
Heat Dissipation:
0.6-0.6 W 50/60 Hz
Coil Technology:
built-in bidirectional peak limiting
Sustainable Offer Status:
Green Premium product
Pollution Degree:
3
Mercury Free:
Yes
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Utilisation Category:
AC-3 || AC-1 || AC-3e
Warranty:
18 months
Operating Altitude:
0...9842.52 ft (0...3000 m)
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Maximum Horse Power Rating:
0.33 hp at 115 V AC 60 Hz for 1 phase motors || 1 hp at 230/240 V AC 60 Hz for 1 phase motors || 2 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 230/240 V AC 60 Hz for 3 phase motors || 5 hp at 460/480 V AC 60 Hz for 3 phase motors || 7.5 hp
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Auxiliary Contact Composition:
1 NO + 1 NC
Range:
TeSys || TeSys Deca
Ambient Air Temperature For Storage:
-60-80°C
Contactor Application:
motor control || resistive load
[Uc] Control Circuit Voltage:
24...60 V AC 50/60 Hz || 24...60 V DC
Hold-In Power Consumption In Va:
0.9-0.9 VA 20°C) 50/60 Hz
$127.00

Description

LC2D09BNE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 24-60V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D09BNE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 4kW@400V. It includes a 24-60V AC/DC low consumption electronic coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 9A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
View AllClose