Schneider Electric

Schneider Electric LC2D12BD TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

(No reviews yet) Write a Review
SKU:
LC2D12BD
MPN:
LC2D12BD
Condition:
New
Time Constant:
28 ms
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Poles Description:
3P
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Utilisation Category:
AC-1 || AC-3 || AC-3e
[Icw] Rated Short-Time Withstand Current:
30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Product Or Component Type:
reversing contactor
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Maximum Operating Rate:
3600 cyc/h 60°C
Protective Treatment:
TH IEC 60068-2-30
Eu Rohs Directive:
Compliant with Exemptions
Device Short Name:
LC2D
Depth:
95 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Operating Time:
53.55...72.45 ms closing || 16...24 ms opening
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Interlocking Type:
mechanical
Pole Contact Composition:
3 NO
Weight:
1.027 kg
Ip Degree Of Protection:
IP20 front face IEC 60529
Minimum Switching Voltage:
17 V for Signaling circuit
Sustainable Offer Status:
Green Premium product
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Uc] Control Circuit Voltage:
24 V DC
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Circularity Profile:
ENVEOLI1102030EN
Mechanical Durability:
30 Mcycles
Country of Origin:
France
Overvoltage Category:
III
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Warranty:
18 months
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Insulation Resistance:
> 10 MOhm for Signaling circuit
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Electrical Durability:
2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
Pollution Degree:
3
Maximum Horse Power Rating:
1 hp at 115 V AC 60 Hz for 1 phase motors || 2 hp at 230/240 V AC 60 Hz for 1 phase motors || 3 hp at 200/208 V AC 60 Hz for 3 phase motors || 3 hp at 230/240 V AC 60 Hz for 3 phase motors || 7.5 hp at 460/480 V AC 60 Hz for 3 phase motors || 10 hp a
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Signaling Circuit Frequency:
25...400 Hz
Protective Cover:
with
$380.00

Description

LC2D12BD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 24V DC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D12BD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 5.5kW@400V. It includes a 24V DC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 24V DC coil for easy integration to all control systems. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 12A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
View AllClose