- Rohs Exemption Information:
- Yes
- Net Weight:
- 0.787 kg
- Electrical Durability:
- 1.65 Mcycles 25 A AC-3 <= 440 V || 1.4 Mcycles 40 A AC-1 <= 440 V || 1.65 Mcycles 25 A AC-3e <= 440 V
- Mounting Support:
- rail || plate
- Product Certifications:
- UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA || CB
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Ambient Air Temperature For Storage:
- -60-80°C
- Sustainable Offer Status:
- Green Premium product
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
- Control Circuit Type:
- AC 50/60 Hz
- Average Impedance:
- 2 mOhm - Ith 40 A 50 Hz for power circuit
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Pvc Free:
- Yes
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Range:
- TeSys || TeSys Deca
- Protective Treatment:
- TH IEC 60068-2-30
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
- Warranty:
- 18 months
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
- Product Or Component Type:
- reversing contactor
- Pole Contact Composition:
- 3 NO
- Fire Resistance:
- 850°C IEC 60695-2-1
- Motor Power Kw:
- 5.5 kW at 220...230 V AC 50-60 Hz || 11 kW at 380...400 V AC 50-60 Hz || 11 kW at 415 V AC 50-60 Hz || 11 kW at 440 V AC 50-60 Hz || 15 kW at 500 V AC 50-60 Hz || 15 kW at 660...690 V AC 50-60 Hz
- Device Short Name:
- LC2D
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || contro
- Maximum Horse Power Rating:
- 3 hp at 230/240 V AC 60 Hz for 1 phase motors || 5 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 3 phase motors || 15 hp at 460/480 V AC 60 Hz for 3 phase motors || 20 hp
- Country of Origin:
- Indonesia
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Eu Rohs Directive:
- Compliant
- Height:
- 85 mm
- Protective Cover:
- with
- Rated Breaking Capacity:
- 450 A at 440 V for power circuit conforming to IEC 60947
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Pollution Degree:
- 3
- Interlocking Type:
- mechanical
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- [Uc] Control Circuit Voltage:
- 240 V AC 50/60 Hz