- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
- [Uc] Control Circuit Voltage:
- 24 V AC 50/60 Hz
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- [Ie] Rated Operational Current:
- 50 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 38 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 38 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Control Circuit Type:
- AC 50/60 Hz
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Poles Description:
- 3P
- Rohs Exemption Information:
- Yes
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 50 A (at 60°C) for power circuit
- Product Or Component Type:
- reversing contactor
- Range:
- TeSys || TeSys Deca
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Electrical Durability:
- 1.4 Mcycles 50 A AC-1 <= 440 V || 1.4 Mcycles 38 A AC-3 <= 440 V
- Net Weight:
- 0.807 kg
- Pole Contact Composition:
- 3 NO
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Environmental Disclosure:
- ENVPEP110229EN
- Depth:
- 92 mm
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Mounting Support:
- rail || plate
- Coil Technology:
- without built-in suppressor module
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
- Mechanical Durability:
- 15 Mcycles
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Height:
- 85 mm
- Pollution Degree:
- 3
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Signaling Circuit Frequency:
- 25...400 Hz
- Product Name:
- TeSys Deca
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Device Presentation:
- preassembled with reversing power busbar
- Circularity Profile:
- ENVEOLI110229EN
- Pvc Free:
- Yes
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Weight:
- 0.807 kg
- Flame Retardance:
- V1 conforming to UL 94
- Protective Cover:
- with
- Ambient Air Temperature For Storage:
- -60-80°C
- Interlocking Type:
- mechanical
- Average Impedance:
- 2 mOhm - Ith 50 A 50 Hz for power circuit
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Maximum Horse Power Rating:
- 5 hp at 240 V AC 60 Hz for 1 phase motors
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Power Dissipation Per Pole:
- 5 W AC-1 || 3 W AC-3
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1