Schneider Electric LC2D50AG7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - coil 120 V AC 60 Hz
Schneider Electric
$752.40
LC2D50AG7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 50A AC-3 22kW@400V, it includes a 120V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D50AG7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 22kW@400V. It includes a 120V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 120V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 50A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
- Mechanical Durability:
- 6 Mcycles
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- [Icw] Rated Short-Time Withstand Current:
- 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Interlocking Type:
- mechanical
- Pole Contact Composition:
- 3 NO
- Protective Cover:
- with
- Maximum Horse Power Rating:
- 3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 h
- Ambient Air Temperature For Storage:
- -60-80°C
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- [Ie] Rated Operational Current:
- 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Coil Technology:
- without built-in suppressor module
- Heat Dissipation:
- 4-5 W 60 Hz
- Rated Breaking Capacity:
- 900 A at 440 V for power circuit conforming to IEC 60947
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Depth:
- 120 mm
- Reach Free Of Svhc:
- Yes
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Eu Rohs Directive:
- Compliant
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 60 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 60 Hz
- Warranty:
- 18 months
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Electrical Durability:
- 1.45 Mcycles 50 A AC-3 <= 440 V || 1.1 Mcycles 80 A AC-1 <= 440 V || 1.45 Mcycles 50 A AC-3e <= 440 V
- Poles Description:
- 3P
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Device Presentation:
- preassembled with reversing power busbar
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Circularity Profile:
- ENVEOLI1503009EN
- Country of Origin:
- United States
- Mercury Free:
- Yes
- Weight:
- 1.88 kg
- Overvoltage Category:
- III
- Device Short Name:
- LC2D
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
- Fire Resistance:
- 850°C IEC 60695-2-1
- Product Or Component Type:
- reversing contactor
- Power Dissipation Per Pole:
- 3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
- Environmental Disclosure:
- ENVPEP1503009EN
- [Uc] Control Circuit Voltage:
- 120 V AC 60 Hz
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Rohs Exemption Information:
- Yes