LC2D65AF7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 65A AC-3 30kW@400V, it includes a 110V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D65AF7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 30kW@400V. It includes a 110V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 110V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
Ip Degree Of Protection:
IP20 front face IEC 60529
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Flame Retardance:
V1 conforming to UL 94
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Interlocking Type:
mechanical
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Certifications:
UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Pollution Degree:
3
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Mounting Support:
plate || rail
Product Name:
TeSys D || TeSys Deca
Product Or Component Type:
reversing contactor
Fire Resistance:
850°C IEC 60695-2-1
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Weight:
1.89 kg
Pvc Free:
Yes
Warranty:
18 months
Net Weight:
1.89 kg
Width:
119 mm
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Environmental Disclosure:
ENVPEP1503009EN
[Icw] Rated Short-Time Withstand Current:
520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Overvoltage Category:
III
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Power Dissipation Per Pole:
9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
Insulation Resistance:
> 10 MOhm for Signaling circuit
Range:
TeSys || TeSys Deca
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Protective Treatment:
TH IEC 60068-2-30
Pole Contact Composition:
3 NO
Protective Cover:
with
Minimum Switching Current:
5 mA for Signaling circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive:
Compliant
Sustainable Offer Status:
Green Premium product
Reach Free Of Svhc:
Yes
Minimum Switching Voltage:
17 V for Signaling circuit
Control Circuit Type:
AC 50/60 Hz
Poles Description:
3P
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947