
Schneider Electric LC2D65AG7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - coil 120 V AC 60 Hz
Schneider Electric
$985.32
LC2D65AG7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 65A AC-3 30kW@400V, it includes a 120V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D65AG7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 30kW@400V. It includes a 120V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 120V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
- Weight:
- 1.89 kg
- Maximum Horse Power Rating:
- 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 50 hp
- Flame Retardance:
- V1 conforming to UL 94
- Rohs Exemption Information:
- Yes
- Heat Dissipation:
- 4-5 W 60 Hz
- Pvc Free:
- Yes
- Device Short Name:
- LC2D
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Signaling Circuit Frequency:
- 25...400 Hz
- Range:
- TeSys || TeSys Deca
- Poles Description:
- 3P
- Ambient Air Temperature For Storage:
- -60-80°C
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Warranty:
- 18 months
- Interlocking Type:
- mechanical
- Motor Power Kw:
- 18.5 kW at 220...230 V AC 50 Hz || 30 kW at 380...400 V AC 50 Hz || 37 kW at 415...440 V AC 50 Hz || 37 kW at 500 V AC 50 Hz || 37 kW at 660...690 V AC 50 Hz
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C)
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Country of Origin:
- France
- Utilisation Category:
- AC-3 || AC-1 || AC-3e
- Width:
- 119 mm
- Reach Free Of Svhc:
- Yes
- [Uc] Control Circuit Voltage:
- 120 V AC 60 Hz
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C)
- Product Certifications:
- UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
- Environmental Disclosure:
- ENVPEP1503009EN
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Eu Rohs Directive:
- Compliant
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Pollution Degree:
- 3
- Product Or Component Type:
- reversing contactor
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Device Presentation:
- preassembled with reversing power busbar
- Depth:
- 120 mm
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Protective Cover:
- with
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
- Height:
- 122 mm
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 60 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 60 Hz
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)