Schneider Electric

Schneider Electric LC2DT40M7 TeSys Deca changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 40 A - 220 V AC coil

(No reviews yet) Write a Review
SKU:
LC2DT40M7
MPN:
LC2DT40M7
Condition:
New
Product Name:
TeSys Deca
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Device Short Name:
LC2D
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Poles Description:
4P
Net Weight:
0.85 kg
Pollution Degree:
3
Environmental Disclosure:
ENVPEP110229EN
Contactor Application:
resistive load
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Pole Contact Composition:
4 NO
Width:
90 mm
Inrush Power In Va:
70-70 VA 60 Hz 0.75 20°C) || 70-70 VA 50 Hz 0.75 20°C)
Ip Degree Of Protection:
IP20 front face IEC 60529
Operating Altitude:
0...9842.52 ft (0...3000 m)
Interlocking Type:
mechanical
Auxiliary Contact Composition:
1 NO + 1 NC
Insulation Resistance:
> 10 MOhm for Signaling circuit
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Coil Technology:
without built-in suppressor module
Protective Cover:
with
[Uc] Control Circuit Voltage:
220 V AC 50/60 Hz
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Weight:
0.85 kg
Product Certifications:
UL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m connector flat Ø 6 mm || power circuit 1.7 N.m connector Philips No 2 || power circuit 1.7 N.m screw cl
Rohs Exemption Information:
Yes
Protective Treatment:
TH IEC 60068-2-30
Circularity Profile:
ENVEOLI110229EN
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Country of Origin:
France
Flame Retardance:
V1 conforming to UL 94
Eu Rohs Directive:
Compliant
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
Mechanical Durability:
15 Mcycles
Depth:
98 mm
Electrical Durability:
1.4 Mcycles 40 A AC-1 <= 440 V
Control Circuit Type:
AC 50/60 Hz
Range:
TeSys || TeSys Deca
Overvoltage Category:
III
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Heat Dissipation:
2-3 W 50/60 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
$601.56

Description

TeSys D changeover contactor, 4 poles (4NO), for non-inductive load applications up to 40A/690V AC-1. It provides 230V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired changeover power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose