Long Time Pick-Up Adjustment Range:
0.25...1 x In
Utilisation Category:
category A
Trip Unit Technology:
electronic, standard, MicroLogic 3.3, LI
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Network Frequency:
50/60 Hz
Pvc Free:
Yes
Suitability For Isolation:
yes IEC 60947-2
Trip Unit Name:
MicroLogic 3.3
Mounting Support:
bracket
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Height:
340 mm
Poles Description:
3P
Protection Technology:
current limiter
Sustainable Offer Status:
Green Premium product
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Storage:
-50-85 °C
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Terminal Identifier:
AL600LS52K3
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Mounting Height:
6 in
Mercury Free:
Yes
Net Weight:
6.2 kg
Phase Connection:
ABC
Ip Degree Of Protection:
front cover IP40
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
Depth:
110 mm
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Ambient Air Temperature For Operation:
-2-70 °C
Communication Interface:
Modbus || Ethernet
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Warranty:
18 months
Device Short Name:
L-Frame
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206029EN
Mounting Mode:
I-Line bracket)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Eu Rohs Directive:
Compliant with Exemptions
Wire Stripping Length:
31 mm || 61 mm
Line Rated Current:
400-400 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact L
Pollution Degree:
3 IEC 60947-1
Environmental Disclosure:
ENVPEP2206029EN
Color:
Black
[Ue] Rated Operational Voltage:
480/277 V AC 50/60 Hz IEC 60947-3
Electrical Connection:
I-Line connection, line || lugs, load
Control Type:
toggle
Device Application:
distribution
Width:
140 mm
Breaking Capacity Code:
D
Rohs Exemption Information:
Yes
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$5,991.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 480VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This breaker is a PowerPact Mission Critical; it analyzes fault current to make decisions which maximize selectivity with downstream circuit breakers. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.