Schneider Electric

Schneider Electric LJL46600U33X Circuit breaker, PowerPacT L, 600A, 4 pole, 600VAC, 25kA, lugs, MicroLogic 3.3S, 80%

(No reviews yet) Write a Review
SKU:
LJL46600U33X
MPN:
LJL46600U33X
Condition:
New
Pvc Free:
Yes
Pollution Degree:
3 IEC 60947-1
Product Name:
PowerPact L
Suitability For Isolation:
yes IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Awg Gauge:
AWG 2/0...500 kcmil aluminium/copper
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Eu Rohs Directive:
Compliant with Exemptions
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Device Application:
distribution
Ambient Air Temperature For Storage:
-50-85°C
Warranty:
18 months
Country of Origin:
United States
Color:
Black
Circularity Profile:
ENVEOLI2206029EN
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Control Type:
toggle
Depth:
110 mm
Product Certifications:
UL || CSA || NOM
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Environmental Disclosure:
ENVPEP2206029EN
Breaking Capacity Code:
J
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Mercury Free:
Yes
Trip Unit Technology:
electronic, standard, MicroLogic 3.3 S, LSI
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Protection Technology:
current limiter
Range:
PowerPact
Trip Unit Name:
MicroLogic 3.3 S
Ip Degree Of Protection:
front cover IP40
Utilisation Category:
category A
Network Frequency:
50/60 Hz
Terminal Identifier:
AL600LS52K4
Length:
31 mm
Line Rated Current:
600-600 A
Device Short Name:
L-Frame
Weight:
6.2 kg
Communication Interface:
Modbus || Ethernet
Rohs Exemption Information:
Yes
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Sustainable Offer Status:
Green Premium product
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Poles Description:
4P
$12,534.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 4 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has lugs on both the line and load sides. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose