- Circularity Profile:
- ENVEOLI1503003EN
- Sustainable Packaging:
- Yes
- Ambient Air Temperature For Operation:
- -25-50°C
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Motor Power Kw:
- 2.2 kW 220...230 V AC 50/60 Hz || 4 kW 380...415 V AC 50/60 Hz || 4 kW 440 V AC 50/60 Hz || 4 kW 480 V AC 50/60 Hz || 4 kW 500...600 V AC 50/60 Hz || 4 kW 660...690 V AC 50/60 Hz
- Net Weight:
- 0.48 kg
- Mercury Free:
- Yes
- Operating Time:
- 30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
- Overvoltage Category:
- III
- Contactor Application:
- motor control || resistive load
- Country of Origin:
- France
- Ip Degree Of Protection:
- IP20 VDE 0106
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
- Mounting Support:
- rail || plate
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Auxiliary Contacts Type:
- instantaneous 1 NC
- Product Name:
- TeSys K
- Utilisation Category:
- AC-1 || AC-4 || AC-3 || AC-3e
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Maximum Operating Rate:
- 3600 cyc/h
- Environmental Disclosure:
- ENVPEP1503003EN
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- Device Presentation:
- preassembled with reversing power busbar
- Weight:
- 0.48 kg
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Sustainable Offer Status:
- Green Premium product
- Hold-In Power Consumption In W:
- 3-3 W 20°C
- Inrush Power In W:
- 3-3 W 20°C)
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Mechanical Durability:
- 5 Mcycles
- [Ue] Rated Operational Voltage:
- power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
- Non Overlap Distance:
- 0.5 mm
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
- Interlocking Type:
- mechanical
- Pole Contact Composition:
- 3 NO
- [Ie] Rated Operational Current:
- 20 A (at <50°C) at <= 440 V AC AC-1 for power circuit || 16 A (at <70°C) at 690 V AC AC-1 for power circuit || 9 A at <= 440 V AC AC-3 for power circuit || 9 A at <= 440 V AC AC-3e for power circuit
- Electrical Durability:
- 1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
- Poles Description:
- 3P
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- [Icw] Rated Short-Time Withstand Current:
- 90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 80 A - 1 s for Signali
- Depth:
- 57 mm
- Mechanical Robustness:
- shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Reach Free Of Svhc:
- Yes
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to NF C 63-110 || 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold