Schneider Electric

Schneider Electric LP5K09004BW3 Changeover contactor, TeSys K, 4P, AC-1, lt or eq to 440V 10A, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP5K09004BW3
MPN:
LP5K09004BW3
Condition:
New
Ip Degree Of Protection:
IP20 VDE 0106
Overvoltage Category:
III
[Uc] Control Circuit Voltage:
24 V DC
Operating Time:
10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
Mechanical Durability:
5 Mcycles
Operating Altitude:
6561.68 ft (2000 m) without derating
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Ambient Air Temperature For Storage:
-50-80°C
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Range:
TeSys
Device Short Name:
LP5K
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Height:
58 mm
Irms Rated Making Capacity:
110 A AC for power circuit conforming to NF C 63-110 || 110 A AC for power circuit conforming to IEC 60947
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Contactor Application:
resistive load
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
[Ie] Rated Operational Current:
20 A (at <50°C) at <= 440 V AC AC-1 for power circuit || 16 A (at <70°C) at 690 V AC AC-1 for power circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Heat Dissipation:
1.8-1.8 W
Pole Contact Composition:
4 NO
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Weight:
0.49 kg
Poles Description:
4P
Reach Free Of Svhc:
Yes
Sustainable Packaging:
Yes
Warranty:
18 months
Inrush Power In W:
1.8-1.8 W 20°C)
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Control Circuit Type:
DC low consumption
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz
Mercury Free:
Yes
Depth:
57 mm
Control Circuit Voltage Limits:
operational: 0.7...1.30 Uc (at <50°C) || drop-out: 0.1...0.7 Uc (at <50°C)
Mounting Support:
rail || plate
Maximum Operating Rate:
3600 cyc/h
Product Or Component Type:
changeover contactor
Environmental Disclosure:
ENVPEP1503003EN
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Device Presentation:
preassembled with reversing power busbar
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Net Weight:
0.49 kg
[Ith] Conventional Free Air Thermal Current:
20 A (at 50°C) for power circuit
Eu Rohs Directive:
Compliant
Ambient Air Temperature For Operation:
-25-50°C