Schneider Electric LRL36600U33X Molded Case Circuit Breaker 600V 400A

(No reviews yet) Write a Review
SKU:
LRL36600U33X
UPC:
3606481029805
Condition:
New
Control Type:
toggle
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mounting Mode:
unit mount lug)
Product Name:
PowerPact L
Breaking Capacity:
200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
Pollution Degree:
3 IEC 60947-1
Poles Description:
3P
Suitability For Isolation:
yes IEC 60947-2
Net Weight:
6.2 kg
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity Code:
R
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Storage:
-50-85 °C
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
Mounting Support:
lug
Electrical Connection:
lugs, line || lugs, load
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
front cover IP40
Communication Interface:
Modbus || Ethernet
Warranty:
18 months
[Ics] Rated Service Breaking Capacity:
150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Network Frequency:
50/60 Hz
Utilisation Category:
category A
Trip Unit Technology:
electronic, standard, MicroLogic 3.3 S, LSI
Eu Rohs Directive:
Compliant with Exemptions
Width:
140 mm
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Color:
Black
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Line Rated Current:
600-600 A
Circuit Breaker Application:
HACR rated
Device Short Name:
L-Frame
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Depth:
110 mm
Mercury Free:
Yes
Device Application:
distribution
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Trip Unit Name:
MicroLogic 3.3 S
Range:
PowerPact
Pvc Free:
Yes
Height:
340 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Continuous Current Rating:
0.8
Environmental Disclosure:
ENVPEP2206029EN
Circularity Profile:
ENVEOLI2206029EN
Wire Stripping Length:
31 mm || 61 mm
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Protection Technology:
current limiter
Terminal Identifier:
AL600LS52K3
Ambient Air Temperature For Operation:
-2-70 °C
$14,295.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 100kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has lugs on both the line and load sides. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose