Schneider Electric LUFDA10 Manual/Auto Reset Func Mod N/O

(No reviews yet) Write a Review
SKU:
LUFDA10
UPC:
3.38911E+12
Condition:
New
Environmental Disclosure:
ENVPEP111201EN
Connection Pitch:
5.08 mm
Circularity Profile:
ENVEOLI111214EN_V1
Tightening Torque:
0.5-0.6 N.m 3.5 mm flat
Current Consumption:
7 mA 24 V DC || 1.1 mA 240 V AC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Auxiliary Contact Composition:
1 NO
Function Available:
thermal overload signalling and automatic or remote reset
Warranty:
18 months
Product Or Component Type:
function module
Discrete Output Function:
1 NO AC-15) 230 V 400 VA 100000 cycles || 1 NO DC-13) 24 V 50 W 100000 cycles
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive:
Compliant with Exemptions
Communication Of Faults:
LED front panel
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mounting Mode:
plug-in
Range:
TeSys
Short-Circuit Protection:
2 A fuse gG IEC 60947-5-1
Mounting Location:
front side
Device Short Name:
LUF
Product Compatibility:
LUCB || LUCC || LUCD
Net Weight:
0.055 kg
Connections - Terminals:
screw clamp terminals 2 0.2-1 mm² flexible without cable end || screw clamp terminals 2 0.2-1 mm² rigid without cable end || screw clamp terminals 2 0.25-1 mm² flexible with cable end || screw clamp terminals 2 0.5-1 mm² flexible with cable end
[Us] Rated Supply Voltage:
24...240 V DC || 24...240 V AC
[Ith] Conventional Free Air Thermal Current:
2 A 70 °C
Input Type:
remote reset 0.2-1.5 mm² <500 m 50 Ohm 52.8 mH 0.093 nF
Catalog:
View
Datasheet:
View
  • Schneider Electric LUFDA10 Manual/Auto Reset Func Mod N/O
  • Schneider Electric LUFDA10 Manual/Auto Reset Func Mod N/O
$156.00

Description

TeSys U additional function module to be inserted in advanced power bases LUB120, LUB320, LUB380 for thermal overload tripping indication. It indicates the overload tripping and the reset done by the power base control pad or done remotely. It provides 1NO instantaneous contact rated 24-250V AC/DC 5A max. It requires an external power supply 24-240V AC or DC. To be inserted in the cavity of a power base provided for the auxiliary modules. Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose