- Ambient Air Temperature For Storage:
- -50-85 °C
- Warranty:
- 18 months
- Mounting Mode:
- I-Line bracket)
- Device Application:
- distribution
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Breaking Capacity Code:
- G
- Awg Gauge:
- 4 x AWG 3/0...500 kcmil aluminium/copper
- Eu Rohs Directive:
- Compliant with Exemptions
- Width:
- 8.27 in
- Poles Description:
- 3P
- Product Name:
- PowerPact P
- Wire Stripping Length:
- 30 mm
- Quality Labels:
- CE
- Circuit Breaker Application:
- HACR rated
- Pollution Degree:
- 3 IEC 60947-1
- Range:
- PowerPact
- Product Or Component Type:
- circuit breaker
- Environmental Disclosure:
- ENVPEP2206033EN
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Rohs Exemption Information:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Electrical Connection:
- I-Line connection, line || lugs, load
- Network Frequency:
- 50/60 Hz
- Pvc Free:
- Yes
- Mounting Height:
- 9 in
- Quantity Per Set:
- 1
- Sustainable Offer Status:
- Green Premium product
- Control Type:
- toggle
- Product Certifications:
- UL || CSA || NOM
- Circularity Profile:
- ENVEOLI2206033EN
- Long Time Pick-Up Adjustment Range:
- 1 In
- Net Weight:
- 32 lb(US)
- Trip Unit Technology:
- electronic, basic, ET 1.0I, I
- Terminal Identifier:
- AL1200P25K
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Tightening Torque:
- 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40
- Line Rated Current:
- 1000-1000 A
- Mounting Support:
- bracket
- Depth:
- 8.05 in
- Height:
- 16.16 in
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Continuous Current Rating:
- 0.8
- Local Signalling:
- 1 trip indicator green)
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mercury Free:
- Yes
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Phase Connection:
- ABC
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Trip Unit Name:
- ET 1.0I
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)