Schneider Electric PGL36080 Molded Case Circuit Breaker 600V 800A
Schneider Electric
$13,905.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Eu Rohs Directive:
- Compliant with Exemptions
- Local Signalling:
- 1 trip indicator green)
- Control Type:
- toggle
- Poles Description:
- 3P
- Product Or Component Type:
- circuit breaker
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Trip Unit Name:
- ET 1.0I
- Quality Labels:
- CE
- Mercury Free:
- Yes
- Long Time Pick-Up Adjustment Range:
- 1 In
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Operation:
- -2-70 °C
- Pollution Degree:
- 3 IEC 60947-1
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Product Certifications:
- UL || CSA || NOM
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Product Name:
- PowerPact P
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Warranty:
- 18 months
- Range:
- PowerPact
- Depth:
- 8.05 in
- Electrical Connection:
- lugs, load || lugs, line
- Circularity Profile:
- ENVEOLI2206033EN
- Height:
- 12.86 in
- Line Rated Current:
- 800-800 A
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Quantity Per Set:
- 1
- Terminal Identifier:
- AL800M23K
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Circuit Breaker Application:
- HACR rated
- Ambient Air Temperature For Storage:
- -50-85 °C
- Wire Stripping Length:
- 25 mm
- Width:
- 8.27 in
- Pvc Free:
- Yes
- Trip Unit Technology:
- electronic, basic, ET 1.0I, I
- Network Frequency:
- 50/60 Hz
- Ip Degree Of Protection:
- front cover IP40
- Environmental Disclosure:
- ENVPEP2206033EN
- Device Application:
- distribution
- Net Weight:
- 32 lb(US)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Continuous Current Rating:
- 0.8
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Breaking Capacity Code:
- G
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View