Schneider Electric

Schneider Electric PJA36025U44A Circuit breaker, PowerPacT P, 250A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 6.0A, 100%, ABC

(No reviews yet) Write a Review
SKU:
PJA36025U44A
MPN:
PJA36025U44A
Condition:
New
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Rohs Exemption Information:
Yes
Quantity Per Set:
1
Product Or Component Type:
circuit breaker
Mounting Height:
9 in
Pvc Free:
Yes
Pollution Degree:
3 IEC 60947-1
Wire Stripping Length:
25 mm
Net Weight:
32 lb(US)
Continuous Current Rating:
0.8
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
distribution
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Environmental Disclosure:
ENVPEP2206033EN
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Trip Unit Name:
MicroLogic 6.0 A
Height:
12.86 in
Mercury Free:
Yes
Length:
25 mm
Quality Labels:
CE
Mounting Support:
bracket
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity Code:
J
Network Frequency:
50/60 Hz
Product Certifications:
UL || CSA || NOM
Sustainable Offer Status:
Green Premium product
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Range:
PowerPact
Line Rated Current:
250-250 A
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Circuit Breaker Application:
HACR rated
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Depth:
8.05 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weight:
32 lb(US)
Poles Description:
3P
Country of Origin:
United States
Phase Connection:
ABC
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Height:
9 in
Terminal Identifier:
AL800M23K
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Ambient Air Temperature For Operation:
-25-70°C
Mounting Mode:
I-Line bracket)
$20,486.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 250A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose