Schneider Electric PLP34100U33A Molded Case Circuit Breaker 480V 1000A

(No reviews yet) Write a Review
SKU:
PLP34100U33A
UPC:
3606486119891
Condition:
New
Line Rated Current:
1000-1000 A
Height:
16.16 in
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Product Certifications:
UL || CSA || NOM
[Ics] Rated Service Breaking Capacity:
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 45 kA 380/415 V AC 50/60 Hz IEC 60947-2
Depth:
8.05 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Name:
PowerPact P
Wire Stripping Length:
30 mm
Circuit Breaker Application:
HACR rated
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Electrical Connection:
terminal nut, line || lugs, load
Trip Unit Name:
MicroLogic 5.0
Network Frequency:
50/60 Hz
Range:
PowerPact
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Quantity Per Set:
1
Sustainable Offer Status:
Green Premium product
Quality Labels:
CE
Pollution Degree:
3 IEC 60947-1
Product Or Component Type:
circuit breaker
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Environmental Disclosure:
ENVPEP1407012EN
Ambient Air Temperature For Operation:
-2-70 °C
Breaking Capacity Code:
L
Eu Rohs Directive:
Compliant
Device Application:
distribution
Rohs Exemption Information:
Yes
Control Type:
toggle
Width:
8.27 in
Ambient Air Temperature For Storage:
-50-85 °C
Mercury Free:
Yes
Continuous Current Rating:
0.8
Poles Description:
3P
Circularity Profile:
ENVEOLI1407012EN
Mounting Support:
lug
Mounting Mode:
unit mount lug)
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Pvc Free:
Yes
Ip Degree Of Protection:
front cover IP40
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
32 lb(US)
Breaking Capacity:
AIR 125 kA 240 V AC 50/60 Hz UL 489 || AIR 100 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 125 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 85 kA 380/415 V AC 50/60 Hz IEC 60947-2
Terminal Identifier:
AL1200P25K
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ue] Rated Operational Voltage:
480 V AC 50/60 Hz UL 489
Catalog:
View
Datasheet:
View
$33,870.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has terminal nuts on the line side and lugs on the load side. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 100kA at 480VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose