Schneider Electric TM3SAC5RG Safety Module For Plc Tm2Xx, 1 Function,

(No reviews yet) Write a Review
SKU:
TM3SAC5RG
UPC:
3606485392981
Condition:
New
Mechanical Robustness:
bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27
Output Thermal Current:
6 A per relay relay output
Device Short Name:
TM3SAC
Ambient Air Temperature For Storage:
-25-70 °C
Relative Humidity:
10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Maximum Cable Distance Between Devices:
30 m
[Us] Rated Supply Voltage:
24 V - 15...20 % DC
Safety Reliability Data:
DC = 95 % ISO 13849-1 || SFF = 95 % IEC 61508-1 || HFT = 1 IEC 61508-1 || type = A IEC 61508-1 || PFHd = 5E-9 1/h IEC 61508-1 || PFHd = 30E-9 1/h IEC 61508-1 || MTTFd = 500 years ISO 13849-1 || MTTFd = 85 years ISO 13849-1
Width:
43.7 mm
Resistance To Magnetic Fields:
30 A/m 50/60 Hz IEC 61000-4-8
Resistance To Fast Transients:
3 kV power lines (DC) DC)IEC 61000-4-4 || 2 kV I/O linesIEC 61000-4-4
Pvc Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
4 kV III IEC 60647-5-1
Storage Altitude:
0-3000 m
Height:
94 mm
Number Of Safety Circuits:
3 NO relay instantaneous opening
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Marking:
CSA || EAC || CE || RCM || UL || TÜV || EFUP 10
Standards:
ISO 13849-1:2008 || ISO 13849-2:2012 || IEC 62061:2005 || IEC 61508:2010 || IEC 60947-5-1:2010 || IEC 61131-2:2007 || IEC 60204-1:2005 || IEC 60204-1:2009/A1 || IEC 61010-1:2010 || EN 50581:2012
Minimum Output Current:
10 mA relay output
Product Or Component Type:
safety module
Maximum Switching Voltage:
230 V AC-15 50 Hz relay instantaneous opening) || 24 V DC-13 relay instantaneous opening)
Mercury Free:
Yes
Current Consumption:
100 mA 24 V DC external supply
Output Voltage:
10 V relay output
Circularity Profile:
ENVEOLI1403010EN
Resistance To Electromagnetic Fields:
10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2 GHz...3 GHz IEC 61000-4-3
Rohs Exemption Information:
Yes
Local Signalling:
for user 6 LEDs (green/red)
Ambient Air Temperature For Operation:
-10-55 °C horizontal installation
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Electromagnetic Emission:
radiated emissions 50 dBµV/m class A 24 V DC)30-230 Hz IEC 61131-3 || radiated emissions 57 dBµV/m class A 24 V DC)230-1000 Hz IEC 61131-3
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Uc] Control Circuit Voltage:
24 V DC
Connections - Terminals:
captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 || captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 || captive
Maximum Response Time On Input Open:
40 ms
Surge Withstand:
1 kV power lines (DC) differential mode IEC 61000-4-5 DC || 1 kV power lines (DC) common mode IEC 61000-4-5 DC
Function Of Module:
emergency stop monitoring 1-channel wiring || emergency stop monitoring 2-channel wiring || monitoring of a movable guard with 2 switches and automatic start
Synchronisation Time Between Inputs:
unlimited
Depth:
73 mm
Pollution Degree:
2
Breaking Capacity:
4 A 24 V 50 ms DC-13 relay output
Breaking Capacity:
360 VA holding AC-15 B300 relay output || 3600 VA inrush AC-15 B300 relay output
Electromagnetic Compatibility:
electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fiel
Resistance To Conducted Disturbances:
10 V 0.15...80 MHz IEC 61000-4-6
Net Weight:
0.19 kg
Electrical Connection:
spring terminal
Safety Module Application:
for emergency stop and switch monitoring
Product Certifications:
UL 61010-2-201 || CSA 61010-2-201 (pending) || TÜV || EAC || CSA Haz Loc Class 1 Division 2 (pending) || ANSI Haz Loc Class 1 Division 2 (pending) || RCM
[Ui] Rated Insulation Voltage:
300 V 2)IEC 60647-5-1
Mounting Support:
top hat type TH35-7.5 rail IEC 60715 || top hat type TH35-15 rail IEC 60715 || wall mount using attached fasteners
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
X
Safety Level:
can reach PL d/category 3 ISO 13849-1 2008 || can reach PL d/category 3 ISO 13849-2 2012 || can reach SILCL 2 IEC 62061 2005 || can reach SIL 2 IEC 61508 2010
Vibration Resistance:
+/- 3.5 mm 5-150 Hz)IEC 60068-2-6
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
[Ith] Conventional Free Air Thermal Current:
18 A
Power Consumption In W:
0.2 W 5 V DC || 3.6 W 24 V DC
Ip Degree Of Protection:
IP20 terminals)IEC 60529
Input Protection Type:
internal, electronic
Environmental Disclosure:
ENVPEP1403010EN
Operating Altitude:
0...6561.68 ft (0...2000 m)
Standards:
IEC 60947-1 || IEC 60204-1 || ISO 13850 || EN 1088/ISO 14119 || IEC 60947-5-1
Output Type:
relay instantaneous opening, 3 NO, potential free
Associated Fuse Rating:
4 A gG or gL relay output IEC 60947-5-1 || 6 A fast blow relay output IEC 60947-5-1
Range Of Product:
Modicon TM3 Safety
Resistance To Electrostatic Discharge:
8 kV in air IEC 61000-4-2 || 6 kV on contact IEC 61000-4-2
$342.50

Description

This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
View AllClose