- Warranty:
- 18 months
- [Ue] Rated Operational Voltage:
- <= 690 V AC 47...63 Hz
- Power Dissipation Per Pole:
- 6.3 W AC-3 - Ith 65 A || 9.6 W AC-1 - Ith 80 A
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz
- Reset:
- remotely or automatically
- Device Presentation:
- direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
- [Ie] Rated Operational Current:
- 65 A (at <50°C) at <= 440 V AC-3 || 80 A (at <50°C) at <= 440 V AC-1
- Utilisation Category:
- AC-1 || AC-2 || AC-3 || AC-4 || AC-3e
- Protection Type:
- thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase reversal || phase loss || phase unbalance || ground current
- Depth:
- 125 mm
- Country of Origin:
- Mexico
- [Uc] Control Circuit Voltage:
- 24 V DC supplied by the bus coupler
- Net Weight:
- 1.248 kg
- Electromagnetic Compatibility:
- electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transient immunity test, level 4, 4 kV, conforming to E
- Ambient Air Temperature For Operation:
- -10-50°C without derating || 50-60°C with current derating
- Function Available:
- upstream voltage presence detection || electrical line and load protection || power and energy monitoring when connected with TPRVM voltage module || safe stop function available when connected with a TPRSM module
- Vibration Resistance:
- 1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
- Current Consumption:
- 80 mA contactor sealed || 500 mA contactor closing
- Halogen Content Performance:
- Halogen free plastic parts product
- Protective Treatment:
- TC
- Motor Starter Type:
- direct on line
- Thermal Protection Adjustment Range:
- 3.35-65 A
- Mounting Mode:
- horizontal and vertical 35 mm symmetrical DIN rail)
- Poles Description:
- 3P 3 NO
- Product Compatibility:
- TPRBC bus coupler || TPRVM voltage interface module || TPRSM SIL interface module
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Sustainable Offer Status:
- Green Premium product
- Tightening Torque:
- 5-5 N.m 1-25 mm² hexagonal 4 mm || 8-8 N.m 25-35 mm² hexagonal 4 mm
- Local Signaling:
- for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
- Device Short Name:
- TPRSS
- [Ith] Conventional Free Air Thermal Current:
- 80 A (at 50°C)
- Operating Altitude:
- 0...6561.68 ft (0...2000 m) without derating
- Maximum Operating Rate:
- 3600 cyc/mn AC-3
- Environmental Disclosure:
- ENVPEP1904009EN
- Connections - Terminals:
- EverLink BTR screw connectors 1 1-35 mm² AWG 16...AWG 2)rigid || EverLink BTR screw connectors 2 1-25 mm² AWG 16...AWG 4)rigid || EverLink BTR screw connectors 1 1-35 mm² AWG 16...AWG 2)flexible without cable end || EverLink BTR screw connector
- Eu Rohs Directive:
- Compliant with Exemptions
- Irms Rated Making Capacity:
- 1000 A at 440 V conforming to IEC 60947
- Ambient Air Temperature For Storage:
- -25-70°C
- Standards:
- EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Shock Resistance:
- 15 gn 11 ms) IEC 60068-2-27
- Fire Resistance:
- 960°C UL 94 || 850°C IEC 60695-2-1 || 650°C IEC 60695-2-12
- Product Name:
- TeSys island
- Relative Humidity:
- 5-95 %
- Safety Function:
- safe stop: category 0 conforming to IEC 60204-1 when associated with a TPRSM module || safe stop: category 1 conforming to IEC 60204-1 when associated with a TPRSM module