Schneider Electric XALD321H29H7 Control Station Xald Three Functions 1 N
Schneider Electric
$143.00
This Harmony XALD yellow control station with 3 functions is ideal for your complete control station. It operates with spring return mechanism and uses screw-clamp terminals. This control station with 3 push buttons for 3 functions enables machine builders to easily add required control and signalling functionality on their machines. Its schematic is clearly distinguishable thanks to clear colors and markings. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product. Vibration resistant screw clamp connection terminals ensure high vibration resistance making product suitable installation on high impact machine.
- Vibration Resistance:
- 5 gn 12-500 Hz)IEC 60068-2-6
- Contacts Material:
- silver alloy (Ag/Ni)
- Operators Description:
- green ''UP'' 1 NO - red ''O'' 1 NC - green ''DOWN'' 1 NO
- Material:
- polycarbonate
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Resistance To High Pressure Washer:
- 7000000 Pa 55 °C 0.1 m
- Positive Opening:
- with EN/IEC 60947-5-1 appendix K
- Net Weight:
- 0.299 kg
- Nema Degree Of Protection:
- NEMA 13 || NEMA 4X
- [Ith] Conventional Free Air Thermal Current:
- 10 A EN/IEC 60947-5-1
- Warranty:
- 18 months
- Operator Profile:
- 3 flush push-buttons
- Ip Degree Of Protection:
- IP66 IEC 60529 || IP69 || IP69K || IP67
- [Ie] Rated Operational Current:
- 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 EN
- Device Short Name:
- XALD
- Electrical Reliability:
- λ < 10exp(-6) 5 V 1 mA EN/IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA EN/IEC 60947-5-4
- Cable Entry:
- 2 knock-outs for cable entry 14-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
- Contact Operation:
- slow-break
- Sustainable Offer Status:
- Green Premium product
- Product Certifications:
- UL Listed || CSA
- China Rohs Regulation:
- X
- Shape Of Screw Head:
- cross Philips no 1 || cross pozidriv No 1 || slotted flat à 4 mm || slotted flat à 5.5 mm
- Ambient Air Temperature For Storage:
- -40-70 °C
- Range Of Product:
- Harmony XALD
- Rohs Exemption Information:
- Yes
- Operating Force:
- 3.5 N NC changing electrical state || 3.8 N NO changing electrical state
- Marking Location:
- marking on legend holder
- Product Or Component Type:
- complete control station
- Colour Of Base Of Enclosure:
- light grey RAL 7035)
- Operating Travel:
- 1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel)
- Environmental Disclosure:
- ENVPEP1806010EN
- Control Station Application:
- three functions
- Standards:
- EN/IEC 60947-5-1 || UL 508 || EN/IEC 60947-5-4 || JIS C8201-5-1 || EN/IEC 60947-1 || CSA C22.2 No 14 || EN/IEC 60947-5-5 || JIS C8201-1
- Ambient Air Temperature For Operation:
- -40-70 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV EN/IEC 60947-1
- Short-Circuit Protection:
- 10 A cartridge fuse gG EN/IEC 60947-5-1
- Reach Free Of Svhc:
- Yes
- Product Destination:
- for XB5 Ã 22 mm control and signalling units
- Shock Resistance:
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Toxic Heavy Metal Free:
- Yes
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Mechanical Durability:
- 10000000 cycles
- Tightening Torque:
- 0.8-1.2 N.m EN/IEC 60947-1
- Connections - Terminals:
- screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
- [Ui] Rated Insulation Voltage:
- 600 V 3)EN/IEC 60947-1
- Colour Of Cover:
- dark grey RAL 7016)
- Electrical Durability:
- 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles
- Control Station Composition:
- 1 flush push-button, red 1 NC O || 1 flush push-button, green 1 NO down || 1 flush push-button, green 1 NO UP
- Circularity Profile:
- ENVEOLI1806010EN
- Mercury Free:
- Yes
- Electrical Shock Protection Class:
- class II IEC 60536
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Protective Treatment:
- TH
- Ik Degree Of Protection:
- IK03 EN 50102
- Catalog:
- View
- Datasheet:
- View