Schneider Electric

Schneider Electric XPSUAB31CC safety module, Harmony XPSU, Cat 1, potential free 2 NC, NO NC, 2 PNP, 48 to 240V AC or DC, spring

(No reviews yet) Write a Review
SKU:
XPSUAB31CC
MPN:
XPSUAB31CC
Condition:
New
Number Of Outputs:
2 on/off configurable pulsed output
[Uimp] Rated Impulse Withstand Voltage:
4 kV II IEC 60947-1
Ambient Air Temperature For Operation:
-25-55°C
Relative Humidity:
5-95 % non-condensing
Minimum Output Current:
10 mA relay output
Sustainable Offer Status:
Green Premium product
Weight:
0.200 kg
Ip Degree Of Protection:
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Environmental Disclosure:
ENVPEP1811003EN
Rohs Exemption Information:
Yes
Type Of Start:
automatic/manual/monitored
Product Certifications:
TÃœV || cULus
Input Compatibility:
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || two-hand control EN 574/ISO 13851-III A || 3-wire proximity
[Ith] Conventional Free Air Thermal Current:
0.125
[Us] Rated Supply Voltage:
48...240 V AC/DC - 10...10 %
Standards:
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
ENVEOLI1811003EN
Input/Output Type:
semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Power Consumption In Va:
6.5 VA 240 V AC 50/60 Hz
Safety Reliability Data:
MTTFd >= 30 years ISO 13849-1 || Dcavg < 60 % ISO 13849-1 || PFHd = 1177E-09 1/h ISO 13849-1 || HFT = 0 IEC 62061 || PFHd = 1177E-09 1/h IEC 62061 || SFF > 60% IEC 62061 || HFT=0 IEC 61508-1 || PFHd = 1177E-09 1/h IEC 61508-1 || SFF > 60% IEC 61508-1
Input Protection Type:
internal, electronic
Auxiliary Contact Composition:
1 C/O
Safety Module Application:
for electrical monitoring of two-hand control stations || for application with safety switchover contact || for emergency stop, guard and light curtain monitoring || monitoring antivalent contacts
[Ui] Rated Insulation Voltage:
250 V 2)IEC 60947-1
Product Or Component Type:
safety module
Power Consumption In W:
2.0 W 48 V DC
Range Of Product:
Harmony Safety Automation
Electrical Circuit Type:
NC pair || PNP pair || antivalent pair || OSSD pair
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Response Time On Input Open:
20 ms
Number Of Inputs:
1 safety input 24 V DC 5
China Rohs Regulation:
X
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Mounting Support:
35 mm symmetrical DIN rail
Safety Module Name:
XPSUAB
Safety Level:
can reach PL = c ISO 13849-1 || can reach SILCL 1 IEC 62061 || can reach SIL 1 IEC 61508
Function Of Module:
emergency stop monitoring 1-channel wiring || guard monitoring 1-channel wiring || monitoring 1 PNP sensor || monitoring two-hand control station type IIIA || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of elec
[Ie] Rated Operational Current:
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally clo
Minimum Output Voltage:
15 V relay output
Net Weight:
0.200 kg
Country of Origin:
Indonesia
Associated Fuse Rating:
6 A gG relay output IEC 60947-1
Mercury Free:
Yes
Synchronisation Time Between Inputs:
0.5 s || 2.2 s
Depth:
120 mm
$226.38

Description

This safety relay is designed for monitoring Emergency stop, Antivalent contacts, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain or Two-hand control stations. The safety relay is powered with 48-240V AC/DC and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 1 safety input, 2 ON/OFF configurable pulsed outputs, 1 single changeover safety output , and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLc/Category 1 conforming to ISO 13849-1, SILCL 1 conforming to IEC 62061 and SIL 1 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÃœV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
View AllClose