Schneider Electric

Schneider Electric BGL26030 Circuit breaker, PowerPacT B, 30A, 2 pole, 600Y/347VAC, 18kA, lugs, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
BGL26030
MPN:
BGL26030
Condition:
New
Local Signaling:
presence of auxiliary contacts flag green)
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Mounting Mode:
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Ambient Air Temperature For Operation:
-25-70°C
Poles Description:
2P
Continuous Current Rating:
0.8
Line Rated Current:
30-30 A
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Control Type:
toggle
Pvc Free:
Yes
Standards:
NMX J-266 || NEMA AB1 || EN/IEC 60947-2 || CSA C22.2 No 5 || UL 489 || EN/IEC 60947-5-1 || GB 14048.2
Breaking Capacity Code:
G
Product Name:
PowerPact B
9 Mm Pitches:
6
Ambient Air Temperature For Storage:
-50-85°C
Connection Pitch:
27 mm
Device Application:
distribution
Color:
Gray RAL 7016)
Depth:
80 mm
Trip Unit Technology:
thermal-magnetic
Network Frequency:
50/60 Hz
Electrical Connection:
Everlink lug, line || Everlink lug, load
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Country of Origin:
Mexico
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Quantity Per Set:
set of 1
Suitability For Isolation:
yes IEC 60947-2
Circuit Breaker Application:
HACR rated
Ik Degree Of Protection:
IK07 conforming to IEC 62262
[Ics] Rated Service Breaking Capacity:
65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
Wire Stripping Length:
20 mm
Environmental Disclosure:
ENVPEP2311047EN
Length:
20 mm
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Quality Labels:
CE
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Ip Degree Of Protection:
front cover IP40 IEC 60529
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 250 V DC UL 489 || 20 kA 600Y/347 V AC 50/60 Hz UL 489
Product Or Component Type:
circuit breaker
Net Weight:
0.769 kg
Weight:
0.769 kg
$1,142.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 30A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose