Schneider Electric

Schneider Electric CAD32X7 TeSys Deca control relay - 3 NO + 2 NC - <= 690 V - 600 V AC standard coil

(No reviews yet) Write a Review
SKU:
CAD32X7
MPN:
CAD32X7
Condition:
New
Environmental Disclosure:
ENVPEP1501004
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Short Name:
CAD
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pole Contact Composition:
3 NO + 2 NC
Weight:
0.58 kg
Insulation Resistance:
> 10 MOhm
Control Circuit Type:
AC 50/60 Hz
Maximum Operating Rate:
180 cyc/mn
Non-Overlap Time:
1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact
Net Weight:
0.58 kg
Minimum Switching Voltage:
17 V
Depth:
84 mm
Product Certifications:
CB || CCC || UL || CSA || EAC || CE || UKCA
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Mechanical Durability:
30 Mcycles
[Ui] Rated Insulation Voltage:
600 V UL || 600 V CSA || 690 V IEC 60947-5-1
Inrush Power In Va:
70-70 VA 50 Hz (at 20°C)
[Ue] Rated Operational Voltage:
<= 690 V AC 25...400 Hz
Ip Degree Of Protection:
IP2X front face VDE 0106
Contactor Application:
control circuit
Minimum Switching Current:
5 mA
Product Or Component Type:
control relay
Warranty:
18 months
Tightening Torque:
1.2 N.m screw clamp terminals Philips No 2 || 1.2 N.m screw clamp terminals flat Ø 6 mm || 1.2 N.m screw clamp terminals pozidriv No 2
Circularity Profile:
ENVEOLI1501004
Product Name:
TeSys CAD
Protective Treatment:
TH IEC 60068
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive:
Compliant with Exemptions
Operating Time:
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
Mounting Support:
rail || plate
Hold-In Power Consumption In Va:
8-8 VA 50 Hz (at 20°C)
Associated Fuse Rating:
10 A gG conforming to IEC 60947-5-1
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Country of Origin:
Mexico
Utilisation Category:
AC-14 || AC-15 || DC-13
Range:
TeSys || TeSys Deca
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C)
Operating Altitude:
0...9842.52 ft (0...3000 m)
Ambient Air Temperature For Storage:
-60-80°C
[Uc] Control Circuit Voltage:
600 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms
$63.25

Description

TeSys D control relay, 5 contacts (3NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 600V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).