Schneider Electric

Schneider Electric GV4PE115N6 Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PE115N6
MPN:
GV4PE115N6
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Short Name:
GV4PE
Eu Rohs Directive:
Compliant with Exemptions
Poles Description:
3P
Color:
Gray RAL 7016)
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Ambient Air Temperature For Operation:
-25-70°C
Maximum Operating Rate:
25 cyc/h
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Phase Failure Sensitivity:
yes IEC 60947-4-1
Ip Degree Of Protection:
IP40 IEC 60529
Rohs Exemption Information:
Yes
Width:
81 mm
Connections - Terminals:
lugs-ring terminals
Device Application:
motor protection
Pvc Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Range:
TeSys Deca
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Control Type:
toggle
Depth:
116 mm
Operating Position:
any position
Product Name:
TeSys GV4 || TeSys Deca
Pollution Degree:
3
Product Or Component Type:
motor circuit breaker
Range Of Product:
TeSys GV4
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Sustainable Offer Status:
Green Premium product
Power Dissipation Per Pole:
4.6 W
Environmental Disclosure:
ENVPEP1704004EN
Trip Unit Technology:
thermal-magnetic || electronic
Warranty:
18 months
Mechanical Durability:
40000 cycles
Fire Resistance:
960°C IEC 60695-2-11
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Halogen Content Performance:
Halogen free plastic parts product
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Magnetic Tripping Current:
1955-1955 A
Climatic Withstand:
IACS E10
Circularity Profile:
ENVEOLI1704004EN
Suitability For Isolation:
yes IEC 60947-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Ambient Air Temperature For Storage:
-50-85°C
Country of Origin:
Poland
$845.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose