Schneider Electric

Schneider Electric GV4PE25N Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PE25N
MPN:
GV4PE25N
Condition:
New
Motor Power Kw:
7.5-7.5 kW 660...690 V AC 50/60 Hz || 5.5-5.5 kW 400...415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 9-9 kW 660...690 V AC 50/60 Hz || 11-11 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 400...415 V AC 50/60 Hz || 9-9 kW 400...415 V AC 50/60 Hz ||
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Warranty:
18 months
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 20000 cycles AC-3 440 V In
Color:
Gray RAL 7016)
Rohs Exemption Information:
Yes
Fire Resistance:
960°C IEC 60695-2-11
Climatic Withstand:
IACS E10
Trip Unit Technology:
electronic || thermal-magnetic
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Name:
TeSys GV4 || TeSys Deca
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Maximum Operating Rate:
25 cyc/h
Device Application:
motor protection
Mercury Free:
Yes
Net Weight:
1.45 kg
Range Of Product:
TeSys GV4
Range:
TeSys Deca
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Operating Altitude:
5000 m
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP1704004EN
Ambient Air Temperature For Operation:
-25-70°C
Weight:
1.45 kg
Circularity Profile:
ENVEOLI1704004EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Type:
toggle
Rated Duty:
continuous IEC 60947-4-1
Ambient Air Temperature For Storage:
-50-85°C
Country of Origin:
Poland
Ip Degree Of Protection:
IP40 IEC 60529
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Line Rated Current:
25 A
Device Short Name:
GV4PE
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Depth:
116 mm
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Sustainable Offer Status:
Green Premium product
Magnetic Tripping Current:
425-425 A
Product Or Component Type:
motor circuit breaker
Halogen Content Performance:
Halogen free plastic parts product
Poles Description:
3P
Phase Failure Sensitivity:
yes IEC 60947-4-1
$695.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 10-25A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose